Promise Technology VTrack M-Class M200i User Manual
Page 291

Chapter 8: Troubleshooting
283
Redundancy Check task 
is queued
Redundancy Check has been set manually or by 
schedule.
Redundancy Check task 
is stopped internally
The logical drive is offline. See page 286.
Resource
Resource is NOT 
available
System resources are low. Reduce system load or 
restart the VTrak. See page 218.
SEP (Storage Enclosure Processor)
SEP is not found
Verify that the SEP is properly installed. See 
page 235 or page 236.
SEP is found
Normal.
Spare Check
Spare check started on 
the given spare drive
Result of settings or user action. Normal.
Spare check completed 
successfully on the given 
spare drive
Normal.
Spare Drives
Physical disk assigned as 
global spare
Result of settings or user action. Normal.
Physical disk is no longer 
assigned as global spare
Result of settings or user action. Normal.
Global Spare has been 
deleted
Result of settings or user action. Normal.
Physical disk assigned as 
dedicated spare
Result of settings or user action. Normal.
Physical disk is no longer 
assigned as dedicated 
spare
Result of settings or user action. Normal.
Dedicated Spare has 
been deleted
Result of settings or user action. Normal.
SMART
SMART error is received
A disk drive reported a SMART error. If this message 
appears repeatedly, replace the disk drive.
Event
Action