Iscsi management, Node, Ports – Promise Technology VTrack M-Class M200i User Manual
Page 203: Node ports

Chapter 5: Management with the CLU
195
iSCSI Management
iSCSI Management deals with all iSCSI settings and functions with the exception
of network connections and settings. This feature appears only with VTrak iSCSI
models. Network connections and settings are discussed under “Network
Management” on page 191.
Node
These functions affect both VTrak iSCSI ports. There are more iSCSI settings
under iSNS Ports, SLP Ports and CHAP.
Note that Header and Data Digest work best with initiators that have a TCP
Offload Engine (TOE).
1.
From the Main Menu, highlight iSCSI Management and press Enter.
2.
Highlight iSCSI Node and press Enter.
Node information appears.
3.
Highlight iSCSI Node Settings and press Enter.
This screen enables you to make iSCSI Node Settings.
4.
Highlight the items you want and press the backspace key to erase the
current value, then type the new value:
•
Node Name
•
Node Alias – Maximum of 32 characters. Use letters, numbers, space
between words and underscore. An alias is optional.
•
Outstanding R2T
•
Maximum Burst Length
•
Default Time to Wait
•
Default Time to Retain
5.
Highlight the items you want to set and press the spacebar to toggle
between Enabled and Disabled:
•
Header Digest
•
Data Digest
•
Unidirectional CHAP Authorization
•
Bidirectional CHAP Authorization
6.
Press Ctrl-A to save your settings.
Ports
1.
From the Main Menu, highlight iSCSI Management and press Enter.
2.
Highlight iSCSI Ports and press Enter.
3.
Highlight iSCSI Port 1 or Port 2 and press Enter.