VTrak M-Class Product Manual
276
Host-interface controller 
settings have changed
Result of user action. Normal.
Fibre Channel
Fibre Channel controller 
has detected bus reset
The initiator sent a reset command. If this message 
appears repeatedly, contact Technical Support. See 
page 299.
Fibre Channel controller 
has received a LUN reset 
command.
Result of user action. Normal.
Fibre Channel controller 
has encountered a fatal 
error
Restart the VTrak. See page 218. If this message 
appears repeatedly, contact Technical Support. See 
page 299.
Fibre Channel link is up
FC link connected and ready. Normal.
Fibre Channel link is 
down
FC link disconnected or otherwise not working.
Fibre Channel controller 
settings have changed
Result of user action. Normal.
iSCSI
iSCSI link is up
iSCSI link connected and ready. Normal.
iSCSI link is down
iSCSI link disconnected or otherwise not working.
Logical Drive
Logical drive initialization 
has started
Result of user action. Normal.
Logical drive initialization 
has completed
Logical drive is ready to use. Normal.
Logical drive initialization 
has paused
Initialization paused because of user intervention, 
schedule or a higher priority background activity.
Logical drive initialization 
has resumed
Initialization has resumed again after a pause.
Logical drive initialization 
has stopped
Initialization stopped because of user intervention, 
schedule or the logical drive was deleted or went 
critical or offline.
Logical drive initialization 
marks the logical drive 
offline
Initialization failure due to a failed disk drive. Replace 
the disk drive, delete and recreate the logical drive. 
See page 16 and page 135.
Event