Promise Technology VTrack M-Class M200i User Manual
Page 282

VTrak M-Class Product Manual
274
Drive-interface controller 
is NOT found
Restart the VTrak. See page 218. If this message 
appears repeatedly, contact Technical Support. See 
page 299.
Drive-interface 
diagnostics has passed
Normal.
Drive-interface 
diagnostics has failed
Restart the VTrak. See page 218. If this message 
appears repeatedly, contact Technical Support. See 
page 299.
Drive-interface controller 
has generated a general/
data parity error.
Drive-to-controller parity error. If this message 
appears repeatedly, contact Technical Support. See 
page 299.
Enclosure
Enclosure temperature is 
above the threshold/
warning threshold
The VTrak is overheating. Check for airflow around 
and through the VTrak, and verify that all fans are 
working. Replace fans as needed.
Enclosure temperature is 
above the critical 
threshold
The VTrak is seriously overheating. Check for airflow 
around and through the VTrak, and verify that all fans 
are working. Replace fans as needed.
Enclosure temperature is 
within the normal range
Normal.
Event Log
Event logging is enabled
Event logging has been successfully enabled.
Event logging is disabled
Event logging has been disabled.
Event log buffer is cleared 
in RAM
The event log was cleared.
Event log buffer is cleared 
in NVRAM
The non-volatile RAM event log was cleared.
Event log buffer is cleared 
in MDD
The MDD (disk drive) event log was cleared.
Host Interface Controller
Host-interface controller 
has detected parity/data 
parity/command parity 
error
A FC/iSCSI error occurred. If this message appears 
repeatedly, contact Technical Support. See 
page 299.
Event
Action