Scsi interrupt status one (sist1), Scsi, Interrupt status one (sist1) – LSI 53C875A User Manual
Page 170: Scsi interrupt, Status one (sist1), Scsi interrupt status one, Sist1), Register: 0x43

4-78
Registers
•
Residual data in the synchronous data FIFO – a
transfer other than synchronous data receive is
started with data left in the synchronous data FIFO.
UDC
Unexpected Disconnect
2
This bit is set when the LSI53C875A is operating in the
initiator mode and the target device unexpectedly
disconnects from the SCSI bus. This bit is only valid
when the LSI53C875A operates in the initiator mode.
When the LSI53C875A operates in low level mode, any
disconnect causes an interrupt, even a valid SCSI
disconnect. This bit is also set if a selection time-out
occurs (it may occur before, at the same time, or stacked
after the STO interrupt, since this is not considered an
expected disconnect).
RST
SCSI RST/ Received
1
This bit is set when the LSI53C875A detects an active
SRST/ signal, whether the reset is generated external to
the chip or caused by the Assert RST bit in the
register. This SCSI reset
detection logic is edge-sensitive, so that multiple
interrupts are not generated for a single assertion of the
SRST/ signal.
PAR
Parity Error
0
This bit is set when the LSI53C875A detects a parity
error while receiving SCSI data. The Enable Parity
Checking bit (bit 3 in the
register) must be set for this bit to become active. The
LSI53C875A always generates parity when sending SCSI
data.
Register: 0x43
SCSI Interrupt Status One (SIST1)
Read Only
Reading the SIST1 register returns the status of the various interrupt
conditions, whether they are enabled in the
7
3
2
1
0
R
STO
GEN
HTH
x
x
x
x
x
0
0
0