Sidewall direct

venting

Vent/air termination – sidewall

Follow instructions below when
determining vent location to avoid
possibility of severe personal injury, death,
or substantial property damage.

A gas vent extending through an exterior
wall shall not terminate adjacent to a
wall or below building extensions such
as eaves, parapets, balconies, or decks.

Failure to comply could result in severe
personal injury, death, or substantial
property damage.

Installation must comply with local
requirements and with the National
Fuel Gas Code, ANSI Z223.1 for U.S.
installations or CSA B149.1 for Canadian
installations.

ƽ WARNING

ƽ WARNING

NOTICE

ƽ WARNING

Do not connect any other appliance to
the vent pipe or multiple boilers to a
common vent pipe. Failure to comply
could result in severe personal injury,
death, or substantial property damage.

Determine location

Locate the vent/air terminations using the following
guidelines:

1. The total length of piping for vent or air must not exceed

the limits given in the General Venting Section on page
21 of this manual.

2. You must consider the surroundings when terminating

the vent and air:
a. Position the vent termination where vapors will
not damage nearby shrubs, plants or air

conditioning equipment or be objectionable.

b. The

fl ue products will form a noticeable plume as

they condense in cold air. Avoid areas where the

plume could obstruct window views.

c. Prevailing winds could cause freezing of

condensate and water/ice buildup where fl ue

products impinge on building surfaces or plants.

d. Avoid possibility of accidental contact of fl ue

products with people or pets.

e. Do not locate the terminations where wind eddies

could affect performance or cause recirculation,

such as inside building corners, near adjacent

buildings or surfaces, window wells, stairwells,

alcoves, courtyards, or other recessed areas.

ƽ WARNING Sidewall vent and air inlet terminations

must terminate in the same pressure
zone.

f. Do not terminate above any door or window.

Condensate can freeze, causing ice formations.

g. Locate or guard vent to prevent condensate damage

to exterior fi nishes.

TO BOILER

INTAKE AIR

CONNECTION

FROM BOILER

VENT PIPE

CONNECTION

VENT / AIR

TERMINATION

GRADE OR

SNOW LINE

12"

MIN

12"

MIN

TO

OVER-

HANG

POSSIBLE ORIENTATIONS

Figure 4-1A PVC/CPVC Sidewall Termination of Air and
Vent

Model

Kit Number

Vent Size

400 - 601

KIT30046

4 inch vent

701 - 801

KIT30048

6 inch vent

Table 4A Sidewall Vent Kits

Do not exceed the maximum lengths of the
outside vent piping shown in FIG. 4-1B.

Excessive length exposed to the outside could
cause freezing of condensate in the vent pipe,
resulting in potential boiler shutdown.

ƽ WARNING

If using the alternate sidewall termination:

3. The air piping must terminate in a down-turned elbow

as shown in FIG. 4-1B. This arrangement avoids
recirculation of fl ue products into the combustion air
stream.

4. The vent piping must terminate in an elbow pointed

outward or away from the air inlet, as shown in FIG. 4-1B.

Figure 4-1B Alternate PVC/CPVC Sidewall Termination
of Air and Vent w/Field Supplied Fittings

Installation & Operation Manual