beautypg.com

Lochinvar 1701 User Manual

Power-fin, Water heater submittal sheet pfx-sub-07

background image

POWER-FIN

®

GAS WATER HEATER 502, 752, 1002, 1302, 1501, 1701 & 2001 MODELS

POWER-FIN

®

WATER HEATER

Submittal Sheet

PFX-Sub-07

JOB NAME ______________________________________________________________________
LOCATION ______________________________________________________________________
ARCH./ENGR.____________________________________________________________________
MECH. CONTRACTOR ___________________________________________________________
MODEL NO. _____________________________________________________________________
TYPE GAS ______________________________________________________________________
Btu/hr INPUT____________________________________________________________________
RECOVERY RATE IN GPH_______________________________________@________°F RISE
NOTES

Standard Features
> Up to 87% Thermal Efficiency (M#)

> Modulating Burner with 5:1 Turndown

> Up to 84% Thermal Efficiency (B#/F#)

> Modulating Burner with 2:1 Turndown (B#)
> On/Off Burner (F#)

> Fan Assisted Sealed Combustion

> Direct-Spark Ignition
> Low NOx Operation
> Low Gas Pressure Operation

> Venting Flexibility

> Category I (B# & F#)
> Category IV Venting (M#)
> Optional Combined Venting Cat. II (M#)

> ASME Copper-Finned Tube Heat Exchanger

> ASME Certified, “HLW” Stamped
> 150 psi ASME T & P Relief Valve
> Gasketless design
> 160 psi working pressure

> SMART SYSTEM Operating Control
> On/Off Switch
> Adjustable High Limit w/ Manual Reset
> Flow Switch
> Low Air Pressure Switch
> Flue Temperature Sensor
> Downstream Test Cocks
> Combustion Air Filtration
> All Bronze Circulating Pump
> Zero Clearances to Combustible Material
> 1 Year Warranty on Parts
> 5 Year Limited Warranty

(See Warranty for Details)

Optional Equipment

Place an X in the box by all options that apply

Alarm Bell
Cupro-Nickel Heat Exchanger
Low Gas Pressure Switch
High Gas Pressure Switch
Low Water Cutoff with Manual Reset
SMART SYSTEM PC Software
Horizontal Air Intake Cap*
Horizontal Vent Cap*
Category IV to II Vent Conversion Kit*
*see venting submittal

Firing Control Systems

(M) indicates 5:1 turndown, Category IV, 502-2001 Models

M9 Hot Surface Ignition with

Electronic Supervision (Standard)

M7 California Code

(B) indicates 2:1 turndown, Category I, 1501-2001 Models

B9

Hot Surface Ignition with
Electronic Supervision (Standard)

B7

California Code

(F) indicates 100% On/Off, Category I, 502-1302 Models

F9

Hot Surface Ignition with
Electronic Supervision (Standard)

F7

California Code