Tk-7150, Adjustment – Kenwood TK-7150 User Manual

Page 41

background image

TK-7150

41

Item

Condition

Measurement

Adjustment

Specifications/Remarks

Test-

equipment

Unit

Terminal

Parts

Unit

Method

ADJUSTMENT

• Narrow

4) CH-SIG : 2-1

Power meter Rear

ANT

Front

Selector ± 1.75kHz

± 0.05kHz

[PF5] key : Set the narrow

Deviation

panel

panel

knob

n_L

meter

Max_Dev_ _

✽✽✽

in tuning mode

AF VTVM

Front

MIC

PTT : ON

AG

panel

Oscilloscope

5) CH-SIG : 1-1

Select n_C

Max_Dev_ _

✽✽✽

in tuning mode

PTT : ON

6) CH-SIG : 3-1

Select n_H

Max_Dev_ _

✽✽✽

in tuning mode

PTT : ON

11. MIC

1) CH-SIG : 1-1

TX-RX

VR700 Check

2.2~3.7kHz

seisitivity

PTT : ON

(Wide only)

Deviation meter filter

HPF : OFF
LPF : 15kHz
De-emphasis : OFF

AG : 1kHz/5mV

12. DQT

1) CH-SIG : 1-1

Front

Selector Wide/Narrow

Flat the A parts.

balance

Select DQT_Bal_ _

✽✽✽

panel

knob

Make the

• Wide

in tuning mode

demodulation wave-

PTT : ON

form neat.

Deviation meter filter

HPF : OFF
LPF : 3kHz
De-emphasis : OFF

• Narrow

2) [PF5] key : Set the narrow

n_ _
DQT_Bal_ _

✽✽✽

in tuning mode

PTT : ON

13. QT

1) CH-SIG : 1-3

± 0.75kHz

± 0.05kHz

deviation

Select QT_Dev_ _ _

✽✽✽

• Wide

in tuning mode

PTT : ON
Deviation meter filter

HPF : OFF
LPF : 3kHz
De-emphasis : OFF

• Narrow

2) [PF5] key : Set the narrow

± 0.35kHz

± 0.05kHz

n_ _
QT_Dev_ _ _

✽✽✽

in tuning mode

PTT : ON

A

A