Tk-7150, Adjustment – Kenwood TK-7150 User Manual
Page 40
TK-7150
40
Item
Condition
Measurement
Adjustment
Specifications/Remarks
Test-
equipment
Unit
Terminal
Parts
Unit
Method
ADJUSTMENT
8. TX high
1) CH-SIG : 3-1
Power meter Rear
ANT
TX-RX
VR1
53W
53.0W± 0.5W
power
Select _ _H
Ammeter
panel
Hi_Power_
✽✽✽
in tuning mode
PTT : ON
Keep data at 256
2) CH-SIG : 2-1
Front
Selector 50W
50.0W± 1W
Select _ _L
panel
knob
11A or less
Hi_Powe_
✽✽✽
in tuning mode
PTT : ON
3) CH-SIG : 1-1
Select _ _C
Hi_Powe_
✽✽✽
in tuning mode
PTT : ON
4) CH-SIG : 3-1
Select _ _H
Hi_Powe_
✽✽✽
in tuning mode
PTT : ON
9. TX low
1) CH-SIG : 2-1
15W
15W± 1W
power
Select _ _L
11A or less
Lo_Power_
✽✽✽
in tuning mode
PTT : ON
2) CH-SIG : 1-1
Select _ _C
Lo_Power_
✽✽✽
in tuning mode
PTT : ON
3) CH-SIG : 3-1
Select _ _H
Lo_Power_
✽✽✽
in tuning mode
PTT : ON
10. Maximum
1) CH-SIG : 2-1
Power meter Rear
ANT
Front
Selector ± 3.8kHz
± 0.1kHz
deviation
Select _ _L
Deviation
panel
panel
knob
• Wide
Max_Dev_ _
✽✽✽
meter
in tuning mode
PTT : ON
AF VTVM
Front
MIC
Deviation meter filter
AG
panel
HPF : OFF
Oscilloscope
LPF : 15kHz
De-emphasis : OFF
AG : 1kHz/50mV
2) CH-SIG : 1-1
Select _ _C
Max_Dev_ _
✽✽✽
in tuning mode
PTT : ON
3) CH-SIG : 3-1
Select _ _H
Max_Dev_ _
✽✽✽
in tuning mode
PTT : ON