Basic requirements, Basic requirements -2 – Kyocera FS-1200 User Manual
Page 21
1.1. Positioning the Printer
1-2
Basic requirements
The printer will work best if it is installed in a location that is:
❒
Near the computer
If the parallel interface is used to connect the printer to the computer, the connecting cable should be
shielded type and not be longer than 3 meters (10 feet).
❒
Level and well supported
Place the printer on a sturdy table or desk. Do not place the printer on an unstable cart, stand, or table. The
printer may fall, causing injury, or serious damage to the printer.
❒
Near an AC wall outlet, preferably one that can be used for the printer alone (see section Power Supply on
next page).
Power requirements are:
The outlet should be earthed, or an adapter should be used.
If an extension cord is used, the total length of the power cord plus extension should be 5 meters (17 feet) or
less.
❒
Well ventilated, not too hot or cold, and not too damp or dry
If you install the printer where the temperature or humidity is outside the above ranges, you may not get
the best print quality, and there will be an increased chance of paper jams.
Voltage
120 V (U.S.A./Canada), 220 V to 240 V (European countries), ±10 % at each voltage
Frequency
60 Hz (120 V), ±2 %
50 Hz/60 Hz (220 V to 240 V), ±2 %
Current capacity
Max. 5.2 A at 120 V, or Max. 2.8 A at 220 V to 240 V
Temperature
10°C to 32.5°C (50°F to 90.5°F)
Humidity
20% to 80%