beautypg.com

Appendix, List of messages – Sony BRC-Z700 User Manual

Page 70

background image

A

ppe

ndix

List of Messages

70

Appendix

List of Messages

The following messages may appear on the screen. Take
the necessary measures shown below.

Indicators on the BRC-Z700 camera

Messages for the BRC-Z700 camera

Error messages for the BRU-H700 HD Optical
Multiplex Unit

Indicator

Meaning/remedies

STANDBY lamp
flashes.

The camera stopped moving due to an
error in the pan/tilt mechanism. Reset
the pan/tilt position or turn off the power
of the camera and turn it on again.

The tally lamp
flashes.

Turn off the power of the camera, and
consult with your Sony dealer.

Message

Meaning/remedies

Please restart system You are prompted to restart the power of

the camera after you changed the setting
of “IMG-FLIP” in the SYSTEM menu.
Use the POWER switch on the supplied
Remote Commander or the POWER
button on the RM-BR300 Remote
Control Unit to turn the power off, then
on. The changed setting becomes
effective.

PRESET xx OK
(xx = preset position
numbers 01 to 16)

When you store the camera settings into
the memory (POSITION 1-16), the
message will appear for 2 seconds.

One Push WB...OK
(NG)

While the white balance is automatically
adjusted, the message will appear. Wait
for a while. When the adjustment is
complete, it will disappear.

STOP

(The message will
flash in FAN
MOTOR on PAGE6
in the STATUS
menu.)

Turn off the power of the camera, and
consult with your Sony dealer.

CAUTION
COOLING FAN 1
(2), (1, 2)
STOPPED!

Turn off the power of the camera, and
consult with your Sony dealer.

*[ENTER]: EXIT

This message appears while you adjust H
PHASE in the SYSTEM menu. To exit
from the adjustment, press the HOME
button on the Remote Commander or the
button on the top of the joystick on the
Remote Control Unit.

*PUSH ENTER
BUTTON

This message appears when you move
the cursor to H PHASE in the SYSTEM
menu. To start the H PHASE adjustment,
press the HOME button on the Remote
Commander or the button on the top of
the joystick on the Remote Control Unit.

PRESET (xx) OUT
OF RANGE (xx =
preset position
numbers 01 to 16)

This message appears when you preset
the camera position when the pan/tilt
position of the camera is out of range of
the current PAN-TILT LIMIT setting.
This camera position presetting will fail
to be performed. Perform the presetting
again after moving the camera within the
range of the PAN-TILT LIMIT setting.

Message

Meaning/remedies

Communication error
Please check
connection

The message will appear when the HD
Optical Multiplex Unit is turned on, if a
problem occurs in the connection of the
Optical Fiber Cable between the camera
and the HD Optical Multiplex Unit.
Turn off the power of the camera and
the HD Optical Multiplex Unit, check
the connection of the Optical Fiber
Cable and turn the powers on again.
This message will also appear when the
power of the camera is not turned on.
Turn off the HD Optical Multiplex Unit,
turn on the camera, then turn on the HD
Optical Multiplex Unit again.

Option card error
Please check option
card

The message will appear when an
Interface Board that cannot be used with
the HD Optical Multiplex Unit is
inserted into the card slot. Turn off the
power of the HD Optical Multiplex Unit
and remove the board.

CAUTION
COOLING FAN
STOPPED!

Turn off the power of the camera, and
consult with your Sony dealer.

Message