Setting of the bottom switches – Sony BRC-Z700 User Manual
Page 19
Ov
er
v
ie
w
Location and Function of Parts
19
N VISCA RS-232C OUT connector
When you connect multiple cameras, connect it to
the VISCA RS-232C IN connector of the next
camera in the daisy chain connection.
O EXT SYNC IN connector
Accepts external video sync signals.
P T VIDEO connector
Outputs the camera images as composite video
signal.
Q
S VIDEO connector
Outputs the camera images as S video signal.
R Card slot
Insert the optional BRBK-HSD1 Output Card or
the BRBK-MF1 Optical Multiplex Card.
The slot cover is attached to the camera at the
factory.
S DC IN 12V connector
Connect the supplied AC power adaptor.
Bottom
T Ceiling bracket mounting screw holes
When you install the camera to the ceiling or on a
shelf, etc. in a high position, secure the supplied
ceiling bracket to these holes using the supplied
four screws. The four feet are attached to the holes
at the factory.
For installation, see “Installing the Camera in a
High Position” on page 55.
U Tripod screw holes (1/4-20UNC)
When you install the camera to a tripod, secure the
tripod to these holes.
V BOTTOM switches
Used for the output signal format selection, RS-
232C/RS-422 selection, baud rate selection, remote
control signal output on/off and camera address
setting.
For details, see “Setting of the BOTTOM switches”
on page 19.
Setting of the BOTTOM switches
1
Switch 1 (59.94i/50i signal format selector)
Set to ON for output of 50i signal format, or OFF
for output of 59.94i signal format.
2
Switch 2 (RS-232C/RS-422 selector)
Set to ON for RS-422, or OFF for RS-232C.
3
Switch 3 (Communication baud rate selector)
Set to ON for 38400bps, or OFF for 9600bps.
4
Switch 4 (Infrared signal output switch)
Set to ON to enable an infrared signal output, or
OFF to disable the output.
5
Camera address selectors
Set the address of the camera.
Normally set to “0”. With this setting, addresses are
assigned to the cameras automatically in the
connected order by pressing the POWER button
while holding down the RESET button on the RM-
BR300 Remote Control Unit.
You can assign the camera address “1” to “7”
manually by setting these selectors as follows:
Switch 4 is not used.
Note
Set the switches before you turn on the power of the
camera.
wa
w;
ws
Camera
address
0
1
2
3
4
5
6
7
Switch 1
OFF ON
OFF ON
OFF ON
OFF ON
Switch 2
OFF OFF ON
ON
OFF OFF ON
ON
Switch 3
OFF OFF OFF OFF ON
ON
ON
ON
O
N
1
2
3
4
O
N
1
2
3
4
2
1
4
5
3