Sun Microsystems GigaSwift Ethernet Adapter User Manual
Page 118
96
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • August 2004
3. At the
ok
prompt, set the
auto-boot?
configuration variable to false.
4. Set the
diag-switch?
parameter to true in order to see the diagnostic power-on
self-test (POST) messages.
5. Reset the system to activate these parameter changes.
6. Use the
show-nets
command to display the list of network devices on the system.
Among the list of devices, you should see the two interfaces specific to the Sun
GigaSwift Ethernet adapter you want to test, as shown in the following example.
Note –
The preceding device paths are examples. The actual device paths on your
system may be different from the examples shown here.
7. Use the
test
command and the device paths found in Step 6, to test the adapter
when you use the FCode self-test.
The structure of the
test
command line that includes the following device
parameters:
Where:
s =
1000, 100, 10, auto
d =
half, full, auto
c =
master, slave, auto
ok setenv auto-boot? false
ok setenv diag-switch? true
ok reset-all
ok show-nets
a) /pci@1f,700000/network@2
b) /pci@1e,600000/pci@4/network@1
c) /pci@1e,600000/pci@4/network@0
q) NO SELECTION
Enter Selection, q to quit:
ok test
device-path
:speed=
s
,duplex=
d
,link-clock=
c
,promiscuous,