beautypg.com

Using the sunvts netlbtest, To use the netlbtest, Using the sunvts – Sun Microsystems GigaSwift Ethernet Adapter User Manual

Page 116: To use the, Netlbtest, Table d-1

background image

94

Sun GigaSwift Ethernet Adapter Installation and User’s Guide • August 2004

Refer to the SunVTS documentation (listed in

TABLE D-1

) for instructions on how to

run and monitor the

nettest

diagnostic. These SunVTS documents are available on

the Solaris on Sun Hardware Collection, which is provided on the Solaris Supplement
CD for the Solaris release on your system.

Using the SunVTS

netlbtest

You must have the Ethernet card and the device driver installed, a loopback
connector in place, and Intervention mode enabled before running

netlbtest

.

netlbtest

cannot run if the network interface is connected to a live network, and

requires that the Ethernet device be configured offline before running the test. Use
the

ifconfig(1M)

command to bring the Ethernet device down before running

netlbtest

.

To Use the

netlbtest

1. Ensure that the SunVTS software and the

ce

driver are installed on your system.

2. Plug in a loopback cable.

3. Unplumb the interface from the system, using the

ifconfig

command

:

Where instance is the instance numbr of the interface.

Refer to SunVTS documentation for instructions on how to run

netlbtest

.

TABLE D-1

SunVTS Documentation

Title

Description

SunVTS User’s Guide

Describes the SunVTS diagnostic environment

SunVTS Test Reference Manual

Describes each SunVTS test (including the

nettest

)

and describes the various test options and
command-line arguments

SunVTS Quick Reference

Provides an overview of the user interface

# ifconfig ce

instance

down

# ifconfig ce

instance

unplumb