Mounting and dismounting cartridge tapes, Mounting and dismounting cartridge tapes -19, Table 3-1. playground cartridge locations -19 – Sun Microsystems TIMBERWOLF 9740 User Manual
Page 51
95693
Revision P
3-19
Operating in Manual Mode
Note: No more than two drive types can be mixed in the 9741/9741E Drive
Cabinet.
Mounting and Dismounting Cartridge Tapes
When you are operating in manual mode, you may need to mount and
dismount cartridge tapes from different types of CTUs and tape drives.
To mount and dismount cartridge tapes:
1. Open the right front door of the LSM by using the door key to unlock the
top and bottom latches. See
.
2. Open the LSM left front door.
•
For the standard door, pull gently from the top right corner.
•
For the expansion door, pull from the recessed area on the right side.
3. To mount a cartridge obtain the VOLSER, location, and drive number from
the operator console. Locate the cartridge and mount it into the drive.
4. To dismount a cartridge, locate the CTU or drive. Remove the cartridge from
the drive and place it outside the LSM.
The following information details the mount and dismount procedures for each
cartridge and device type. Proceed to the appropriate section for information
about the specific drive installed in the LSM.
Note: See
for examples of operator panel displays.
Table 3-1. Playground Cartridge Locations
Drive Combinations
Diagnostic Cell
Cleaning Cell
9490
25
23
SD-3
26
24
9490
SD-3
25
26
23
24
DLT
26
24
T9840
25
23
T9940
25
23
T9840
DLT
25
26
23
24
T9940
T9840
25
26
23
24
T9940
DLT
25
26
23
24