Connecting and Switching on the Computing Unit

Release 04/02

3-20

Panel PC 670 Computing Unit, Equipment Manual

Connecting the computing unit via an adapter

An adapter is available for connecting the computing unit to the PLC with earlier
standard connecting cables.

Table 3-1

Adapters for connecting the computing unit

Interface

Connection

Connecting cable

Order No.

Adapter

6ES5 734-2BF00

COM 1 as

Computing unit to a SIMATIC S5

6ES5 731-1xxx0
15-pin

6ES5 731-6AG00

TTY port

programmable controller

6ES5 731-0xxx0
25-pin

6ES5 731-6AG00

In order to maintain a data transmission rate of 9600 bps up to a distance of 1000 m,
the receive diode is connected to ground (reference) via the connecting cable.

Note

Lengths deviating from the standard connection cable (6ES5 734-2BF00) can be
obtained using Order No. 6ES5 734-2xxx0, whereby xxx stands for the cable
length length code.