beautypg.com

Siemens PC 670 User Manual

Page 178

background image

Technical Data

Release 04/02

A-2

Panel PC 670 Computing Unit, Equipment Manual

A.1

Technical Data of the Panel PC 670 Computing Unit

General

Order nos.

See order documentation

Dimensions

297x267x80 (WxHxD in mm), without CD-ROM drive
297x267x101 (WxHxD in mm), with CD-ROM drive

Weight

approx. 6kg (13.5 lbs.)

Supply voltage (U

N

)

120 V (85 V to 132 V (AC),
or 230 V (170 V to 264 V) AC (autorange)

alternative: 24 V (20.4 bis 28.8 V) DC, SELV

(Line voltage frequency, AC

50/60 Hz (47 to 63 Hz)

Short-term power interruption complying to to
Namur

max. 20 ms at 0.85 U

N

(max. 10 times per hour; min. recovery time 1 s)

Max. power consumption

120W

max. current output (DC), according to form of
power supply

+5V/ 13,5A

3,3V/ 8,5A

+12V/ 2,5A

–12V/0,3A

(in total max. 105W)

Noise emission

< 55dB(A) to DIN 45635

Degree of protection

IP20

Safety

Protection class

Protection class I pursuant IEC 60536

Safety specifications with AC power supply

UL1950/IEC 60950 entspr. DIN VDE 0805, UL 508

Safety specifications with DC power supply

UL508

Electromagnetic compatibility (EMC)

Emitted interference with power supply 105W

EN 55022 Class A (requirement for industrial sector)
for devices with AC power supply EN6100-3-2 class D
and EN61000-3-3

Emitted interference with power supply 85W

EN 55022 Class B (requirement for domestic and
industrial sector)
for devices with AC power supply EN6100-3-2 class D
and EN61000-3-3

Noise immunity:

Mains borne disturbance variables on supply
lines

±

2 kV

(to IEC 61000-4-4; Burst)

±

1 kV

(to IEC 61000-4-5; Surge symm)

±

2 kV

(to IEC 61000-4-5; Surge unsymm)

Noise immunity on signal lines

±

1 kV

(IEC 61000-4-4; Burst; length < 5 m)

±

2 kV

(IEC 61000-4-4; Burst; length > 5 m)

±

2 kV

(to IEC 61000-4-4:1995; Surge unsymm;
length > 30 m)

Noise immunity to discharges of static electricity

±

6 kV contact discharge

(to IEC 61000-4-2)

±

8 kV discharge in air

(to IEC 61000-4-2)

Noise immunity to high-frequency radiation

10 V/m 80-1000 MHz, 80% AM (to IEC 61000-4-3)

10 V/m 900 MHz and 1,89 GHz, 50% ED
(to IEC 61000-4-3)

10 V 9KHz- 80MHz

(to IEC 61000-4-6)

Magnetic field

30 A/m 50Hz

(to IEC 61000-4-8)