7.4.4

Watchdog (WD)

Function

The watchdog monitors the execution of a program. The purpose of the WD is to
report a program crashing to the user by means of different reactions.

After switching on the computing unit or after a HW-RESET (cold start) the
watchdog remains in standby, i.e. no WD reaction is activated and the RUN-LED
remains switched off. If the watchdog is activated (by driver or SOM program) the
Run LED is green.

WD-Reaktionen

If the WD is not retriggered within the set time (by driver or SOM program), the
following reactions are triggered:

Reaction

Options

RUN LED switches from green to red

Always

Acknowledge WD

Always

Initiate reset on the computing unit

Adjustable

IRQ an die Rechnereinheit absetzen

Adjustable

SOM application is displayed

Adjustable

The reactions you want to have triggered can be set by drivers or the SOM
program.

WD monitoring times TWD

The monitoring times can be adjusted in increments of one second over the range
from 3 to 255 seconds.

Note

If the watchdog time is modified after the watchdog has been activated – in other
words, while the watchdog is running – the watchdog will be retriggered as a
result!