Hardware Information

Release 04/02

7-24

Panel PC 670 Computing Unit, Equipment Manual

Internal serial interface COM2 (V.24), X26

This port is connected in parallel to the external COM2 port. Both ports can
therefore only be used as alternately. They are assigned such that a 1:1
connection can be established to a 9-pin D-SUB socket when insulation
displacement connectors are used. The maximum cable length is 100 cm at a data
rate of 9.6 kbaud.

Pin
No.

Short Name

Meaning

Input/Output

1

DCD

Data carrier detect

Input

2

DSR

Data set ready

Input

3

RxD

Received data

Input

4

RTS

Request to send

Output

5

TxD

Transmission data

Output

6

CTS

Clear to send

Input

7

DTR

Data terminal equipment ready

Input

8

IP

Incoming call

Input

9

GND

Functional ground (reference
potential)

-

10

P5V

+5V power supply

Output

7.5.3

Assignment of internal interfaces on the mainboard

Interface

Position

Connector

Description

Memory

Internal

X19, X20

2 SO-DIMM slot, 64Bit

Processor

Internal

X1

Socket for MMC2 mobile processor

Bus expansion

Internal

X10

Socket for bus extender, assigned with
ISA and PCI bus signals

Power supply
105W

Internal

X13

20 pin connector for DC signals of the
power supply unit with 85W

Floppy

Internal

X5

two drives are possible (82078 compati-
ble)
360kB, 720kB, 1.2MB, 1.44MB
3F0h-3F7h, 370h-377h, can be disabled
IRQ 6, edge-triggered
26 pin, socket for flex-lead (notebook con-
nection)

3.5” hard disk

Internal

X41

170h-177h, 1F0h-1F7h, can be disabled
IRQ14, IRQ15, edge-triggered
40 pin, 2.54mm male connector (3.5” HD,
primary),
a maximum of two drives can be connec-
ted