Communication failure, Fault messages, Ignition failure – State Industries SHE50-100PE User Manual

Page 68

background image

66

Servicing should only be performed by a Qualified Service Agent

fault messages

displayed message/condition/indicates

possible causes - checK/repair

Ignition Failure

The Control System has detected less than 1.0 μA (dC

micro amps) through the flame sensor during the Ignition

Verification operating state on three consecutive trials for

ignition.

CHANGE

BACK

ADVANCED

Ignition Failure

Fault occurred 2 mins ago

The water heater has failed to

ignite the burner.

Call a service professional:

Your Company Name Here

(press [DOWN] for more....)

Important Service Reminder:

When performing any troubleshooting steps outlined in

this manual always consider the wiring and connectors

between components. Perform a close visual inspection

of all wiring and connectors to a given component before

replacement.

• Check for flame sensing current during the Ignition

Verification operating state. Perform the Flame

Sensing Current Test on page 19.

• The Combustion Blower and Burner Assembly must

be removed to access the Burner, Flame Sensor

and the Igniter. If the preceding checks have failed

to identify the cause for the Ignition Failure, remove

the Burner Assembly for a thorough inspection. See

Figure 5 on page 9 and Combustion Blower and

Burner Removal on page 14.
Ensure the Blower discharge orifice is installed

properly in the top of the Burner Adapter during

disassembly, see Figure 11 on page 13.

Clean the Flame Sensor with fine steel wool - check for

signs of excessive wear, bent, damage, cracks in the

insulator - replace Flame Sensor if worn or damaged.

Check/adjust the gap between the Flame Sensor and

the Burner, this gap should be approximately 1/2 inch.

See Flame Sensor on page 18.

Inspect the Burner Adapter wiring harness for signs of

wear or damage. Repair/replace as necessary.

Remove the Burner from the end of the Burner

adapter and check for any debris that may be clogging

the Burner. If the Burner is clogged with debris or

damaged, replace the Burner.

• Call the toll free support phone number on the back

cover of this manual for further assistance if the

problem has not been corrected after performing the

procedures outlined here.

Communication Failure

The Control System has detected a loss of communications

between the CCB and the uIM.

CHANGE

BACK

ADVANCED

Communication Failure

Fault occurred 2 mins ago

Communications between the

user interface module and the

central control board could not

be established.

Call a service professional:

Your Company Name Here

(press [DOWN] for more....)

• Turn off power - check the communication cable

connections between the J2 Socket on the uIM

circuit board and the J16 Port on the CCB, see uIM

(user Interface Module) on page 37 and CCB (Central

Control Board) on page 39.

• Replace the communication cable (standard category

V network cable) between the CCB and the uIM.

• Call the toll free support phone number on the back

cover of this manual for further assistance if the

problem has not been corrected after performing the

procedures outlined here.