beautypg.com

Energy cut out (eco), Fault messages – State Industries SHE50-100PE User Manual

Page 62

background image

60

Servicing should only be performed by a Qualified Service Agent

fault messages

displayed message/condition/indicates

possible causes - checK/repair

Energy Cut out (ECo)

The Control System has detected water temperature in

the water heater storage tank above 201°F (94°C). Tank

temperature must cool to 140°F (60°C) before the fault

message (lock out) can be reset.

CHANGE

BACK

ADVANCED

Energy Cut Out (ECO)

Fault occurred 2 mins ago

Tank temperature is excessive.

The water heater has been

disabled.

Call a service professional:

Your Company Name Here

(press [DOWN] for more....)

Important Service Reminder:

When performing any troubleshooting steps outlined in

this manual always consider the wiring and connectors

between components. Perform a close visual inspection

of all wiring and connectors to a given component before

replacement.

• Be extremely careful - record temperature from a

nearby hot water fixture.

• If recorded temperature is above 180°F - shut off

power and gas to the water heater and call the toll

free support phone number on the back cover of

this manual for further assistance. DO NOT lEAvE

THE WATER HEATER IN OPERATION UNDER ANy

CIRCuMSTAnCES.

• If recorded temperature from above is below 180°-

cycle power to reset the Control System. Watch the

water heater through several heating cycles. If tank

temperature climbs above the current operating Set

Point by more than 5° F (2.8° C) - shut off power

and gas to the water heater and call the toll free

support phone number on the back cover of this

manual for further assistance. DO NOT lEAvE THE

WATER HEATER IN OPERATION UNDER ANy

CIRCuMSTAnCES.

• Check Temperature Probe plug and socket

connection at CCB’s J7 Socket (page 41). Perform a

close visual inspection of the pins inside the plug

and socket - ensure plugs and sockets are mating

properly and providing good contact.

• Check all wiring between the Temperature Probe and

the J7 Socket on the CCB. Repair/replace anything

worn or damaged.

Perform the ECo Continuity Test on page 36. If

there is no continuity between these two wire

ends in the Temperature Probe plug end and the

tank temperature is not excessive - replace the

Temperature Probe.

• Call the toll free support phone number on the back

cover of this manual for further assistance if the

problem has not been corrected after performing the

procedures outlined here.

This manual is related to the following products: