beautypg.com

Display settings, Heater information, Display settings heater information – State Industries SHE50-100PE User Manual

Page 53

background image

51

Servicing should only be performed by a Qualified Service Agent

display settings

description/action

display

Select display Settings from the Main Menu and press the

operational Button under "SELECT" to enter this menu. This

menu contains adjustable display options for viewing information

on the LCd screen. use the up & down Buttons to navigate the

menu.

Temperature Units - Adjustable user setting that changes

temperature units display to Celsius °C or Fahrenheit °F.

backlight delay - Adjustable user setting that determines

how long the LCd backlight remains illuminated after a key

has been pressed. Available settings are; Always off, 10,

30 or 60 seconds and Always on.

Contrast - Adjustable user setting to adjust the LCd screen

contrast between text and background.
note: These settings are adjusted in the same way

described for the operating Set Point and differential

Adjustment.

Temperature Units

°F

Backlight Delay

30s

Contrast

60%

CHANGE

BACK

HELP

Display Settings

heater information

description/action

display

Select Heater Information from the Main Menu and press the

operational Button under "SELECT" to enter this menu. This

menu contains non adjustable operational information.

Elapsed Time - Total accumulated time the Control System

(water heater) has been energized.

Burner on Time - Total accumulated time the Control

System has been in the heating operating state; Burner run

time.

Cycle Count - Total accumulated count of heating cycles.

CCB Version - Software version for central control board.

UIM Version - Software version for user interface module.
note: Historical data is stored in the CCB's memory. If this

CCB is replaced during servicing the historical data on the

CCB being replaced will be lost. The data stored in the new

circuit board will no longer reflect the entire history of the

water heater.
The Elapsed Time, Burner on Time and Cycle Count indicate

age, usage and wear.
If the Cycle Count per day is high (divide cycle count by days)

or the cycle duration is short (divide Burner on Time by cycle

count) consider rasing the differential setting to avoid short

cycling and excessive component wear, see operating Set

Point And differential Adjustment on page 49.
This historical data can also be used to assist facilities

managers in forecasting planned replacement of equipment

to help avoid lengthy and costly hot water supply interruptions.

Elapsed Time

10 day 0 hrs 0 mins

Burner On Time

5 hrs 22 mins

Cycle Count

00000035

CCB Version

X.XX

UIM Version

X.XX

CHANGE

BACK

HELP

Heater Information

This manual is related to the following products: