beautypg.com

State Industries SHE50-100PE User Manual

Page 23

background image

21

Servicing should only be performed by a Qualified Service Agent

IGNITER CURRENT TEST AT J5 SOCKET ON CCB

IGNITER CURRENT TEST BEHIND CCB ENCLOSURE

Figure 21

Service Notes:

• The animated lighting bolt Status Icon is visible on the LCd desktop Screen during the Igniter warm up

operating state. See desktop Screen on page 46 and Status Icons on page 47.

• As a visual confirmation that minimum Igniter current is present the Control System will display a check

mark next to the lighting bolt icon on the desktop Screen during the Igniter Warm up operating state.

• Ensure the wiring and connections between the J5 Socket on the CCB and the Burner Adapter are not

broken, pinched or disconnected.

• Ensure there is approximately 120 VAC at the J5 Socket on the CCB during Igniter Warm up.
• It is a good practice to check igniter current when any service or maintenance is being performed.

Igniter current will be approximately 0.60 to 0.70 AC amps when the Igniter is new. Because hot surface

igniters are wearing parts they can cause intermittent ignition failure with age and wear. Replacing the

Igniter when current is lower than 0.55 AC amps is a good preventive maintenance procedure that can

prevent loss of hot water and customer dissatisfaction.

This manual is related to the following products: