15

Servicing should only be performed by a Qualified Service Agent

6. disconnect the 24 Volt power wires to the 24 Volt Gas Valve at the two spade connectors in the wiring

harness to the valve, see Figure 14 below.

7. disconnect the Blower Prover switch sensing tube from the Combustion Blower outlet sensing port, see

Figure 14 below.

8. Turn off the supply gas to the water heater at the main gas shutoff valve serving the water heater.
9. disconnect the supply gas line to the water heater at the water heater's 24 Volt Gas Valve.
10. If the water heater has been installed in a direct Vent configuration, disconnect the intake air pipe at the

intake air connection on the water heater, see Figure 14 below.

11. Loosen the hose clamp closest to the Venturi on the Intake Air Elbow and remove the Intake Air Elbow

and Intake Air Connection fitting as assembled unit, see Figure 14 below.

12. using a small socket wrench with a 1/8 inch hex attachment or a long (8-10”) T handle 1/8 inch hex (allen

key) wrench remove the four hex head machine screws that hold the Combustion Blower to the Burner

Adapter, see Figure 15 on page 16.

13. Lift the Combustion Blower up and off of the Burner Adapter, see Figure 15 on page 16.
14. Remove the orange silicone gasket.
15. Ensure the Blower discharge orifice is present and seated properly on top of the Burner Adapter, see

Figure 10 on page 13.

16. See the Service notes below for additional information.
combustion blower installation
17. To re-install the Combustion Blower follow the steps for removal in reverse order.
18. Install a new orange silicone gasket between the Combustion Blower and the Burner Adapter.
19. do not overtighten the Combustion Blower hex head screws during installation, torque should be

approximately 3 foot lbs.

20. Restore power to the water heater and run it through at least one complete heating cycle before leaving

to ensure it is operating properly.

INTAKE AIR CONNECTION FITTING

VENTURI

COMBUSTION BLOWER ASSEMBLY TOP VIEW

HOSE

CLAMP

INTAKE AIR

ELBOW

COMBUSTION BLOWER

OUTLET SENSING PORT

24 VOLT GAS VALVE

WIRING HARNESS

SPADE CONNECTORS

SUPPLY GAS CONNECTION

24 VOLT GAS VALVE

COMBUSTION

BLOWER

Figure 14