beautypg.com

Southbend 18' & 60: EVS Toolroom Lathes 220v sb1016 User Manual

Page 19

background image

For Machines Mfg. Since 7/09

Model SB1016/SB1036

-17-

P R E P A R A T I O N

— If one or more pump motors do not pump

or rotate in the incorrect direction, locate
the master power switch on the lathe,
and swap any two of the L1, L2, or L3
incoming power leads shown in Figure 4.

Ground

Hot

Hot

Hot

DISCONNECT

SWITCH

(as recommended)

L3

L2

L1

MASTER

POWER SWITCH

L3

L3

L2

L2

L1

L1

1

2

3

5

6

4

Figure 4. Machine incoming power supply wires.

Swap any

Two of

These Wires

2.

Close the electrical cabinet door, reinstall

motor covers and access panels, and test
machine operation.

Figure 5. Component locations in lathe electrical

cabinet.

Variable Frequency

Drive (Figure 3)

Master Power

Switch (Figure 4)