A-6
P470/370 RF Scanner Product Reference Guide
According to AIM standards, a UPC with supplemental bar code is transmitted in one of the
following formats:
]E0 (UPC chars) (terminator) ]E2 (supplemental) (terminator) or
]E2 (supplemental) (terminator) ]E0 (UPC chars) (terminator)
In the scanner, however, the format is changed to:
]E0 (UPC chars) ]E2 (supplemental)
Therefore, a UPC with two supplemental characters, 01234567890510, is transmitted to
the host as a 21-character string, ]E00012345678905]E110.
Table A-4. Symbol Code Identifier Characters
Code Type
Symbol Identifier
UPC-A, UPC-E, EAN-13, EAN-8
A
Code 39
B
Codabar
C
Code 128
D
Code 93
E
Interleaved 2 of 5
F
Discrete 2 of 5, D 2 of 5 IATA
G
MSI Plessey
J
UCC/EAN 128
K
Bookland EAN
L
Trioptic Code 39
M