11-14
•
key: Changeover unit of figures
HEX
(hexadecimal)
OCT
(octal)
DCM
(decimal)
Bit pattern
Turn to program mode (stop PC operation). Setting of parameters is only available when the PC is
in program mode.
Select parameter setting mode.
Write "00
(H)
" to parameter address 007777
(8)
and stop operation
of the JW-21MN. Setting of the parameter is only available
when the operation of the JW-21MN is stopped.
Connect a support tool with the JW-21MN.
JW-14PG/13PG/12PG
JW-50SP
JW-50PG, Z-100LP2S
- For operation of each support tool, see the instruction
manual attached. The following describes an example
of JW-14PG's key operation.
Note: Setting parameters is unavailable by JW-2PG.
(JW-14JG)
JW-21MN
007777
(8)
Screen display of JW-14PG
Indications in [ ] of each item mean as follows:
(Example) Stop operation of data link [HEX (hexadecimal), byte]
This means to set "stop operation" by hexadecimal and byte unit.
"Run" the slave station PC
Turn "ON" the power of the master station PC and connect support tools
Stop PC operation
Stop operation of data link [HEX (hexadecimal), byte]
Stop PC operation
Display the contents of parameter
address 007777 by hexadecimals.
Write
00
(H)
.
Reference
To the next page
0 0
(H)
07775 HEX 00
07776 HEX 1F
I PARAM.
>07777 HEX 00
Function of JW-14PG
- key: Byte display Changeover word display
(Set parameter)
Select initial mode