Sharp JW-21MN User Manual
Page 32
8
8-4
* ME-NET addresses (SEG10 to 2C) of file 10 to 2C
(H)
are out of ranges of the ME-NET
specification. These are special addresses for the JW-21MN.
- Available addresses vary with PC model on which the JW-21MN is installed and its capacity.
For details, see an instruction manual for each PC.
(2) Memory address map (against JW30H)
*
JW30H address
(8)
ME-NET address
(8)
Capacity
Remarks
Relay
SEG0 00000.0 to 1577.7
7168 points
Bit
address
Extension relay
SEG0 30000.0 to 35577.7
23552 points
TMR/CNT contact points
SEG0 01600.0 to 01777.7
512 points
SEG0 35600.0 to 35777.7
512 points
Relay
0000 to
1577
SEG0 00000 to 01577
896 bytes
Byte
address
Extension relay
2000 to
7577
SEG0 30000 to 35577
2944 bytes
TMR/CNT current value
b2000 to b3777
SEG0 26000 to 27777
1024 bytes
Register
09000 to 09777
SEG0 04000 to 04777
512 bytes
19000 to 19777
SEG0 05000 to 05777
512 bytes
29000 to 29777
SEG0 06000 to 06777
512 bytes
39000 to 39777
SEG0 07000 to 07777
512 bytes
49000 to 49777
SEG0 10000 to 10777
512 bytes
59000 to 59777
SEG0 11000 to 11777
512 bytes
69000 to 69777
SEG0 12000 to 12777
512 bytes
79000 to 79777
SEG0 13000 to 13777
512 bytes
89000 to 89777
SEG0 14000 to 14777
512 bytes
99000 to 99777
SEG0 15000 to 15777
512 bytes
E0000 to E5777
SEG0 16000 to 23777
3072 bytes
Register (storable error
history)
E6000 to E7777
SEG0 24000 to 25777
1024 bytes
TMR/CNT number
0000 to 1777
0000 to 1777
1024 pcs.
-----
File
register
File 1
000000 to 037777
SEG1 000000 to 037777
16 K bytes
Byte
address
File 2
000000 to 177777
SEG2 000000 to 177777
64 K bytes
File 3
000000 to 177777
SEG3 000000 to 177777
64 K bytes
File 10
(H)
000000 to 177777
SEG10 000000 to 177777
64 K bytes
File 10
(H)
000000 to 177777
SEG11 000000 to 177777
64 K bytes
:
:
:
:
File 1F
(H)
000000 to 177777
SEG1F 000000 to 177777
64 K bytes
File 20
(H)
000000 to 177777
SEG20 000000 to 177777
64 K bytes
File 21
(H)
000000 to 177777
SEG21 000000 to 177777
64 K bytes
:
:
:
:
File 2C
(H)
000000 to 177777
SEG2C 000000 to 177777
64 K bytes
Program
address
JW-31CUH/H1
000000 to 016777
SEG8 000000 to 016777
7680 steps
-----
JW-32CUH
000000 to 036777
SEG8 000000 to 036777
15872 steps
JW-32CUH1
000000 to 036777
SEG8 000000 to 036777
15872 steps
000000 to 076777
SEG8 000000 to 076777
32256 steps
JW-33CUH/H1
000000 to 076777
SEG8 000000 to 076777
32256 steps
JW-33CUH2/H3
000000 to 076777,
100000 to 176777
SEG8 000000 to 076777,
SEG9 000000 to 076777
64512 steps