beautypg.com

Sharp JW-21MN User Manual

Page 63

background image

11-10

[Example for setting]
The master station and slave station 01 and 02 are JW-21MN.
It shows example for setting that slave station 01 is data link (standard function) and slave station 02 is
data link (save memory function with 30H mark).

: Send
: Receive

Master

station

(Standard)

Slave station 01

(Save memory)

Slave station 02

Off set

(4 bytes)

Off set

(8 bytes)

4 bytes

8 bytes

8 bytes

8 bytes

Relay
link area

Register
link area

Flag
area

8 bytes

4 bytes

8 bytes

16 bytes

8 bytes

8 bytes

24 bytes

Flag
24 bytes

Station No.
information

Station No.
information

Flag
24 bytes

Station No.
information

No mark -- Setting by parameter of master station

------------ Setting by parameter of slave station

----------- Setting by module No. switch of slave station

Top address of relay link area

Number of off set bytes of relay link area

Number of sending bytes of relay link

Number of receiving bytes of relay link

Top address of register link area

Number of off set bytes of register link area

Number of sending bytes of register link

Number of receiving bytes of register link

Top address of flag area

Station number information output

Slave station 1

(standard)

0200

4 bytes

0400

8 bytes

0740

Yes

Slave station 2

(save memory)

1000

4 bytes

8 bytes

4 bytes

09000

8 bytes

8 bytes

8 bytes

19000

Yes

Maser station

0210

8 bytes

0400

16 bytes

0740

Yes