Sharp JW-21MN User Manual
Page 110
16-15
- Network setting
Select whether the target station for remote programming or remote monitor is on the
standard network connection or on the extension network connection.
In the case below, 10 to 12
(8)
are standard network connections. 01 to 03
(8)
are extension
network connections.
< Expansion network connection >
ME-NET
Slot number
ME-NET
Target station
0
1
2 3
01
(8)
00
(8)
11
(8)
10
(8)
12
(8)
(Junction station)
02
(8)
03
(8)
(JW-50PG)
Set "standard" in network configuration.
Set the target station number (00 to 77
(8)
).
Set "ME-NET" in target station model.
Set "extension" in network configuration.
(In the case of the above figure: 02
(8)
)
(In the case of the above figure: 12
(8)
)
(Keep the initial value "0" )
Set the installed slot number of the master station
on the target station side. In the case of the above
figure: 3.
Set the target station number "ME-NET."
Set "ME-NET" in junction station model.
Set the junction station rack number.
Set the target station number (00 to 77
(8)
).
Set the junction station number (00 to 77
(8)
).
Set the station slot number.