11-6
Corresponding symbols on pages 11-7 to 11-9
-
to
are equivalent to number of page 11-13.
- Parameter addresses other than above mentioned are reserved areas and prohibited to be changed.
- When the JW-21MN is a slave station, set the top address and the number of sending bytes so
that the data can be within the setting range of each area (see pages 11-7 to 11-12). When any
slave stations are except JW-21MN, see the instruction manual of each device.
Set item
Parameter
address
(8)
Initial
value
(H)
Details (set range)
*
e
Flag area top
address
(communication
and PC operation
status monitor flag)
007764
E0
File address lower digits
Set range: See page 11-11 to
11-12.
- Initial value: 01E0
(H)
to
000740
(8)
(
0740)
e
0
007765
01
File address upper digits
007766
00
File number
007767
80
Flag output (Yes: 80
(H)
, No: 00
(H)
)
r
- Start/stop
operation of the
JW-21MN
- Write to the JW-
21MN EEPROM.
007777
01
Select "00, 01, 08, 80, 81" with hexadecimal notation.
(See page 16-12.)
---