beautypg.com

Sharp JW-21MN User Manual

Page 107

background image

16-12

(5 / 5)

- For initial values of above addresses, see page 11-5 and 6.

(2) Slave station (01 to 77

(8)

)

(1 / 1)

- For initial values of above address, see page 11-22.

Address(8)

Set contents

Setting method (value, example)

Bit address

7 6 5 4 3 2 1 0

007750

07 06 05 04 03 02 01 00

007751

17 16 15 14 13 12 11 10

007752

27 26 25 24 23 22 21 20

007753

37 36 35 34 33 32 31 30

007754

47 46 45 44 43 42 41 40

007755

57 56 55 54 53 52 51 50

007756

67 66 65 64 63 62 61 60

007757

77 76 75 74 73 72 71 70

Connection condition of slave station
- Turn ON the corresponding bit of

connected station number (01 to
77

(8)

) from the list at right.

- 00

(8)

of master station (0 bit of

address 000750)

At ON: Output error code
At OFF: Do not output error code.

007750

to

007757

- When connecting slave station 00

to 04

(8)

and output error code:

(Address)

(Bit pattern)

007750

00011111

007751

00000000

to to
007757

00000000

00

(H)

01

(H)

Do not output

Output

Whether the station number information should
be output or not

007763

(Octal, word)

00

(H)

007764

to

007767

007764

007765

007766

007767

Flag area top address on the master
station

When 0200, set to 000200

(8)

(Set by file address)

00

(H)

: Do not output flag

80

(H)

: Output flag

00

(H)

01

(H)

80

(H)

81

(H)

08

(H)

Stop operation of the JW-21MN

Start operation of the JW-21MN

Writing to EEPROM or operation of the JW-
21MN/stop operation
Writing to EEPROM or operation of the JW-
21MN/start operation

Initialize parameter settings

007777

Stop operation of the JW-21MN

Start operation of the JW-21MN

Writing to EEPROM or operation of the JW-
21MN / stop operation
Writing to EEPROM or operation of the JW-
21MN / start operation

Initialize parameter settings

Address

(8)

Set contents

Setting method (value, example)

007720
007721

Number of receiving bytes of relay link in save
memory function

007722
007723

Number of receiving bytes of register link in save
memory function

00

(H)

01

(H)

Whether the station number information should
be output or not

007763

(Octal, word)

00

(H)

007764

to

007767

007764

007765

007766

007767

Top address of flag area on each
slave station

When 0600, set to 000600

(8)

(Set by file address)

00

(H)

: Do not output flag

80

(H)

: Output flag

00

(H)

01

(H)

80

(H)

81

(H)

08

(H)

007777

Do not output

Output

If 0 is set, the number of bytes will be
the same as the number of transfer
bytes set in the master station.

If 0 is set, the number of bytes will be
the same as the number of transfer
bytes set in the master station.

(Octal, byte)

(Octal, byte)

V2

V2

V2

V2