Sharp JW-21MN User Manual
Page 107
16-12
(5 / 5)
- For initial values of above addresses, see page 11-5 and 6.
(2) Slave station (01 to 77
(8)
)
(1 / 1)
- For initial values of above address, see page 11-22.
Address(8)
Set contents
Setting method (value, example)
Bit address
7 6 5 4 3 2 1 0
007750
07 06 05 04 03 02 01 00
007751
17 16 15 14 13 12 11 10
007752
27 26 25 24 23 22 21 20
007753
37 36 35 34 33 32 31 30
007754
47 46 45 44 43 42 41 40
007755
57 56 55 54 53 52 51 50
007756
67 66 65 64 63 62 61 60
007757
77 76 75 74 73 72 71 70
Connection condition of slave station
- Turn ON the corresponding bit of
connected station number (01 to
77
(8)
) from the list at right.
- 00
(8)
of master station (0 bit of
address 000750)
At ON: Output error code
At OFF: Do not output error code.
007750
to
007757
- When connecting slave station 00
to 04
(8)
and output error code:
(Address)
(Bit pattern)
007750
00011111
007751
00000000
to to
007757
00000000
00
(H)
01
(H)
Do not output
Output
Whether the station number information should
be output or not
007763
(Octal, word)
00
(H)
007764
to
007767
007764
007765
007766
007767
Flag area top address on the master
station
When 0200, set to 000200
(8)
(Set by file address)
00
(H)
: Do not output flag
80
(H)
: Output flag
00
(H)
01
(H)
80
(H)
81
(H)
08
(H)
Stop operation of the JW-21MN
Start operation of the JW-21MN
Writing to EEPROM or operation of the JW-
21MN/stop operation
Writing to EEPROM or operation of the JW-
21MN/start operation
Initialize parameter settings
007777
Stop operation of the JW-21MN
Start operation of the JW-21MN
Writing to EEPROM or operation of the JW-
21MN / stop operation
Writing to EEPROM or operation of the JW-
21MN / start operation
Initialize parameter settings
Address
(8)
Set contents
Setting method (value, example)
007720
007721
Number of receiving bytes of relay link in save
memory function
007722
007723
Number of receiving bytes of register link in save
memory function
00
(H)
01
(H)
Whether the station number information should
be output or not
007763
(Octal, word)
00
(H)
007764
to
007767
007764
007765
007766
007767
Top address of flag area on each
slave station
When 0600, set to 000600
(8)
(Set by file address)
00
(H)
: Do not output flag
80
(H)
: Output flag
00
(H)
01
(H)
80
(H)
81
(H)
08
(H)
007777
Do not output
Output
If 0 is set, the number of bytes will be
the same as the number of transfer
bytes set in the master station.
If 0 is set, the number of bytes will be
the same as the number of transfer
bytes set in the master station.
(Octal, byte)
(Octal, byte)
V2
V2
V2
V2