Error information – Sanyo PJ-Net Organizer Plus POA-LN02 User Manual
Page 80

0
Chapter 5 Network Capture
error messages
Cause and corresponding
Set up the parameter.
Error when executing the communication. The parameter setting
(host name, capture port) has not been set.
C
heck parameter setting ( p.67)
It has not been registered to
monitor as a group.
Error when executing Start Communication or Start real time cap-
ture. The IP address of the computer has not been registered.
R
egister the IP address by using the web browser ( p.72)
Cannot be displayed as moni-
tor is under display.
Error when executing Start Communication or Start real time cap-
ture. The other capture, viewer or advanced card imager function
is now operating.
W
ait until the communication function is available.
Cannot connect to monitor.
Cannot establish the connection with the network unit when
executing the Start communication, End communication, Capture
transfer, Start real time capture or End real time capture.
C
heck connection of the network cable.
Cannot transfer data to moni-
tor.
Cannot transfer the data to the network unit when executing the
Start Communication, End Communication, Capture transfer, Start
real time capture or End real time capture. The time out period is
10 seconds.
C
heck connection of the network cable.
Cannot receive data from mon-
itor.
Cannot receive the data from the network unit when executing
the Start Communication, End Communication, Capture transfer,
Start real time capture or End real time capture. The time out
period is 10 seconds.
C
heck connection of the network cable.
Other PC has authority.
Cannot complete "Network
Communication".
When executing the End communication, you cannot quit the
communication because other computer has an authority
Other PC has authority. Cannot
obtain authority.
Other computer has an authority.
The server name or address
could nt be resolved.
When setting the parameter, the computer cannot find the set-
ting host name or IP address in the network.
U
se available host name or IP address.
Invalid port number
When setting the parameter, the reserved port number is speci-
fied.
C
heck parameter setting ( p.67)
Monitor
has not started Network
Communication. Close the window
and open it again.
The monitor might have turned off during the communication.
C
heck monitor power and restart executing "Start communication".
error information
Network capture function is for projector originally. So some error
messages include word "PJ". Here "PJ" means "Monitor".