beautypg.com

Using ezset, Manual output level adjustment – JBL CVPD50 User Manual

Page 51

background image

51

Using EzSet

The JBL Cinema Vision EzSet (main)
remote makes it possible to quickly and
accurately set the output levels without
the use of a sound-pressure meter,
although manual adjustment is also avail-
able. However, for the easiest setup, fol-
low these steps while seated in the listen-
ing position that will be used most often:

1. Make certain that all speaker positions

have been properly configured for their
“large” or “small” settings and turn off
the OSD system if it is in use.

2. Adjust the volume so that it is at –2dB,

as shown in the on-screen display or
Lower Display Line E.

3. Press and hold the SPL Button j

until the red LED under the SPL
Button j
lights and the LCD screen
in the remote changes to the display
shown in Figure 24. (You may also nav-
igate to the screen shown in Figure 24
by pressing and holding the Remote
Menu Button

b for 3 seconds until

the main remote menu appears; then
scroll to the SET SPKR LEVELS option
and press the Set Button s.)

Figure 24

4. Press the Set Button j within 5

seconds so that the screen shown in
Figure 25 appears. Press the

/

¤

Navigation Controls q until the
lower line of the remote’s LCD display
shows the number of speakers in your
system. (Don’t count the subwoofer.)
For example, if you have left, center,
right, side surround left and right, and
back surround left and right speakers
for a full 7.1 system, press the button
twice so that the bottom line reads
7 CHANNELS, as shown in Fig. 25.

Figure 25

5. Hold the remote in front of you at arm’s

length, being sure not to cover the
EzSet Microphone Sensor at the top of
the remote, and press the Set Button
j
within 5 seconds to begin the
EzSet calibration process. At this point,
EzSet will take control of your system,
starting the test tone at the front left
speaker, and automatically adjusting
the output level so that it is correct.
During the adjustment, the Lower
Display Line E

will display the

speaker position on the left side of the
display and the offset from reference
level on the right side of the display.
As the levels are adjusted, the speaker
position and a level indication will
appear in the bottom line of the
remote’s LCD display (Figure 26).

Figure 26

• The channel position being adjusted

will flash in the Speaker/Channel
Input Indicators F
. If the test noise
is heard from a channel other than the
one shown in the indicator, there is an
error in the speaker connections. If this
is the case, press the Remote Menu
Button

b to stop the adjustment.

Then turn the unit off and verify that all
speakers are connected to the proper
Speaker Outputs ¡™£¢.

• During the adjustment process for each

channel, you will see indications of
LOW, HIGH and a level readout in

.

This is normal, and it confirms that
EzSet is doing its job of changing the
levels to match the desired reference.

• If a channel cannot be adjusted to the

proper reference level, you will see
FAIL displayed in the remote’s bottom
LCD line before the test tone moves to
the next channel. This is usually an
indication that the volume control was
set too low. When EzSet stops circulat-
ing the tone through all channels and
returns to normal, adjust the volume
level and repeat the procedure from
Step 3.

6. After the test noise has circulated once

through each channel, it will send the
tone to each channel once again, to
verify the settings.

7. After two complete circulations of the

tone, the levels are set. Upon comple-
tion of the second circulation, the LCD
Information Display

2 will flash

COMPLETE four times and then go
out. The tone will stop and the CVR700
will return to normal operation.

If you find that the output levels cho-
sen by EzSet are either uncomfortably
low or high, you may repeat the proce-
dure. Return to Step 2 and adjust the
master volume either slightly higher or
lower to accommodate your particular
room layout and your tastes. You may
repeat this procedure as many times
as necessary to achieve a desired
result. In order to prevent possible

damage to your hearing or your equip-
ment, it is important to avoid setting
the master volume above 0dB.

NOTE: The subwoofer output is not
adjusted when the test tone is in use. To
adjust the subwoofer output, you must
use an external source, following the
instructions on page 64.

Manual Output Level
Adjustment

Output levels may also be adjusted man-
ually, either to set them to a specific
level with an SPL meter, or to make fine
tuning adjustments to the levels obtained
using the EzSet remote. In order to adjust
the subwoofer’s output level, you must
use the manual adjustment method.

Manual output level adjustment may be
performed using either the on-screen
SPEAKER LEVELS submenu,
or using the main remote control.

Using the On-Screen Menu System

With the

SPEAKERS submenu on

screen, scroll down to the

LEVELS

line and press the Set Button s

.

The

SPEAKER LEVELS submenu

(Figure 27) will appear. All of the values
should be set at

0 dB. If not, you may

wish to scroll down to the

RESET

THESE SETTINGS line and press
the Set Button s

effect the reset.

Figure 27

Scroll down to the

TEST TONE line

and use the /› Navigation Controls
q

so that ON appears. The inter-

nal test tone will begin to circulate from
speaker to speaker in a clockwise direc-
tion and will be heard from all speakers
in turn, playing for two seconds in each
speaker before continuing, and a blinking
on-screen cursor will appear next to the
name of each speaker location when the
sound is at that speaker.

Alternatively, you may leave the test tone
turned off and play a favorite piece of
program material, such as a CD music
selection or a DVD movie. With the
SPEAKER LEVELS submenu on
screen you will be able to adjust the out-
put levels using the source material as a
reference.

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

38

39

40

41

31

32

30

28

29

25

26
27

28

29

30

24
23
22

21

20

31

37
36

35

34

33

32

31

37
36

35

34

33

32

48

49

50

51

47
46

45

44

43

42

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

* SPEAKER LEVELS *
FRONT LEFT : 0 dB
CENTER : 0 dB
FRONT RIGHT : 0 dB
SIDE SURR RIGHT: 0 dB
BACK SURR RIGHT: 0 dB
BACK SURR LEFT : 0 dB
SIDE SURR LEFT : 0 dB
SUBWOOFER : 0 dB
RESET THESE SETTI NGS?
TEST TONE : OFF
BACK TO SPEAKERS MENU

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

38

39

40

41

31

32

30

28

29

25

26
27

28

29

30

24
23
22

21

20

31

37
36

35

34

33

32

31

37
36

35

34

33

32

48

49

50

51

47
46

45

44

43

42

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

38

39

40

41

31

32

30

28

29

25

26
27

28

29

30

24
23
22

21

20

31

37
36

35

34

33

32

31

37
36

35

34

33

32

48

49

50

51

47
46

45

44

43

42

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

E

Z

S

E T

C H A N N E L S : 7

S P E A K E R : 1 6 8

d

d B

S E L E C T

# S P K R S

7 C H A N N E L S

S E T S P K R L E V E L S
E

Z

S

E T

CVR700 OM 12/17/04 4:24 PM Page 51

This manual is related to the following products: