Milwaukee LSM40MP-2 User Manual
Page 32

32
NOTE:.DIAGRAMS.&.ILLUSTRATIONS.ARE.NOT.TO.SCALE.
1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210
Figure 59
Step 8..Reassemble.the.remaining.components.
by. reversing. the. procedures. outlined. in. the.
preceding.steps...
Step 9..Attach.the.conversion.label.provided.
in.the.conversion.kit.to.the.rating.plate.on.the.
appliance.
Step 10..Turn.on.gas.supply.and.test.for.gas.
leaks.
Step 11.. Attach. manometer. to. the. manifold.
side.pressure.test.fitting.and.verify.manifold.
pressure.reads.3.5.inches.water.column.(0.87.
kPa). for. natural. gas,. and. 10.0. inches. water.
column.(2.49.kPa).for.propane.gas.
ALWAYS TEST PRESSURES WITH THE VALVE
REGULATOR CONTROL AT THE HIGHEST
SETTING.
Step 7...(Refer.to.Figure 56 on Page 31 and
Figure 59)
VERIFY THE PROPER ORIFICE SIZE BE-
FORE INSTALLING IT.
A..Remove..the.orifice.from.the.manifold.and.
replace.it.with.the.one.provided.in.the.kit..See.
the.following.table.for.orifice.sizes.for.natural.
and.propane.models
. Figure 59 illustrates.
the. orifice.. . Use. pipe. joint. compound. or.
Teflon.tape.on.all.pipe.fittings.before.installing.
(ensure.propane.resistant.compounds.are.
used.in.propane.applications,.do.not.use.pipe.
joint.compounds.on.flare.fittings)..
B..Retrieve.the.burner.and.slide.the.venturi.tube.
over.the.orifice...Set.the.burner.assembly.
into.its.position.and.secure.it.
C..Reinstall.the.grate.assembly..
Step 6...Refer.to.Figure 58 .and.remove.the.
pilot.hood.assembly.to.access.the.hexed.pilot.
orifice...Remove.and.replace.the.orifice.with.
the.one.provided.with.the.kit.
SIT Millivolt Gas
Valve Shown
Pressure
Regulator
Remove
These
Components
Figure 57
Millivolt & Electronic Gas Valves
HI
LO
SIT Electronic Gas Valve
Pressure
Regulator
SIT Millivolt Pilot Assembly Shown
Figure 58
Pilot
Orifice
Thermopile
(on millivolt
pilot assem-
blies only)
Millivolt & Electronic Pilot Assemblies
SIT Electronic Pilot
Pilot
Orifice
Burner Orifice Sizes
Elevation 0-4500 feet ( 0-1372 meters)
Model
Nat.Gas
drill size (inches)
Propane
drill size (inches)
LSM40-2 .1405" (#28)*
• H2286
.086" (#44)*
• H2287
LSM45-2
.161" (#20)*
• H2288
.093" (#42)*
• H4816
Table 9
* Standard size installed at factory
• Part /Cat. Number
Printed.in.U.S.A..©.2005.by.Lennox.Hearth.Products
P/N 850,026M REV. E 03/2010
Lennox.Hearth.Products.reserves.the.right.to.make.changes.at.any.time,.without.notice,.in.
design,.materials,.specifications,.prices.and.also.to.discontinue.colors,.styles.and.products..
Consult.your.local.distributor.for.fireplace.code.information.