Caution, Warning – Milwaukee LSM40MP-2 User Manual
Page 27

NOTE:.DIAGRAMS.&.ILLUSTRATIONS.ARE.NOT.TO.SCALE.
27
Figure 52 - Burner Flame Appearance
(Rustic Oak Logs Shown) LSM45-2
Figure 51 - Burner Flame Appearance
(Birch Logs Shown) LSM40-2
To.adjust.the.flame,.rotate.the.air.shutter.toward.
the.back.or.toward.the.front.of.the.fireplace..
Position.the.air.shutter.to.the.factory.setting.as.
shown.in.the.table.in.
Figure 50...Allow.the.burner.
to.operate.for.at.least.15.minutes...Observe.the.
flame.continuously..If.it.appears.weak.or.sooty.
as.previously.described,.adjust.the.air.shutter.
until.the.flame.appearance.is.as.desired..
Use the extension knob (refer to Figure 38), to
adjust the flame height as desired, by sliding
the knob over the variable flame adjustment
knob located on the front of the valve. Replace
the extension knob back to the hanger after
the adjustment.
Propane.models.may.exhibit.a.flame.pattern.
that. may. candle. or. appear. stringy.. If. this. is.
problematic. or. persists. as. the. appliance. is.
continually. operated,. adjust. the. air. shutter.
closed.as.described.in.the.previous.paragraphs..
Operate.the.appliance.for.a.period.of.time.as.the.
effect.diminishes,.ensuring.that.the.appliance.
does.not.develop.sooty.flames...When.satisfied.
that.the.appliance.operates.properly,.proceed.
to.finish.the.installation.
Leave.the.control.knob.in.the.ON.position.and.
the.remote.switch.OFF.
CAUTION
Soot will be produced if the air
shutter is closed too much. Any
damage due to carboning result-
ing from improperly setting the
air shutter is not covered under
the warranty.
Air Shutter
Opening
Burner
Orifice
Gas
Valve
Venturi
Venturi
Main Burner Factory Air Shutter
Opening Setting - Inches (millimeter)
Model
Nat.Gas
Propane Gas
LSM40-2
1/16 (1.59)
9/32 (7.14)
LSM45-2
1/16 (1.59)
9/32 (7.14)
Figure 50
WARNING
•
Air shutter adjustment should
only be performed by a quali-
fied professional service
technician.
•
Ensure that the front glass
door assembly is in place and
sealed After adjustment.
Burner Air Shutter Adjustment Procedure