Milwaukee LSM40MP-2 User Manual
Page 20

20
NOTE:.DIAGRAMS.&.ILLUSTRATIONS.ARE.NOT.TO.SCALE.
Figure 33
- Top Vent - THREE 90 DEGREE ELBOWS
See.Table 8 on Page 19..as.an.aid.in.venting.component.selection.for.a.particular.range.of.exterior.wall.thicknesses.
V
H
H1
Wall Firestop/Spacer
(SV8HF)
Wall Firestop/Spacer
(SV8HF)
Ceiling
Firestop/Spacer
(SV8BF)
V
H
H1
V1
Wall Firestop/Spacer
(SV8HF)
Ceiling
Firestop/Spacer
(SV8BF)
Wall
Firestop/Spacer
(SV8HF)
Ceiling
Firestop/Spacer
(SV8BF)
Table D
H
+ H
1
Maximum
V Minimum
feet
(meter)
feet
(meter)
3.5
(1.07)
2.5
(0.762)
6.5
(1.98)
3.5
(1.07)
8.5
(2.6)
4.5
(1.37)
10.5
(3.2)
5.5
(1.68)
12.5
(3.8)
6.5
(1.98)
14.5
(4.4)
7.5
(2.3)
16.5
(5.0)
8.5
(2.6)
18.5
(5.6)
9.5
(2.9)
20
(6.0)
10
(3.0)
V +
H
+ H
1
= 40 feet (12.4 m) Max.
H
+ H
1
= 20 ft. (6.2 m) Max.
Table E
H
+ H
1
= 20 feet (6.2 m) Max.
V
+ V
1
+
H
+ H
1
= 40 ft. (12.4 m) Max.
V = 2.5 feet Min. (0.762 m)
V
+ V
1
= 11 feet (3.35 m) Min. for LSM40-2
V
+ V
1
= 10.5 feet (3.2 m) Min. for LSM45-2
HORIZONTAL VENT FIGURES/TABLES
(continued)
Figure 32
- Top Vent - TWO 90 DEGREE ELBOWS
See.
Table 8 on Page 19 .as.an.aid.in.venting.component.selection.for.a.particular.range..of.
exterior.wall.thicknesses.