19. arc voltage error selection, 20. stick check selection – Miller Electric Welder User Manual
Page 123
![background image](/manuals/118529/123/background.png)
OM-196 188 Page 117
1
Monitor Display
Provides a means to enable/dis-
able the arc voltage error feature
and to set an acceptable range of
deviation from set arc voltage or arc
length (trim) before the error will ac-
tuate.
When this feature is off, arc voltage
or arc length variations will not
cause an error or shut the unit
down.
When this feature is on and a range
of deviation is set (the range limits
are
±
0.1 to 9.9 volts from desired
weld voltage, and
±
0.1 to 9.9 sec-
onds), arc voltage or arc length
variations outside of the defined
range, for a period of time exceed-
ing the defined acceptable time pe-
riod, cause either the error relay to
energize or the unit to shut down
depending on the Arc Start/Volt
Sense shutdown error setting.
Jog IPM
Flow
> Monitor
Stick
Arc Volts
> On
2.0 Volts
1.0 Sec
Arc Volts
> Off
1
.
When a system reset is
done, Monitor is set to Off.
14-19. Arc Voltage Error Selection
Press Mode
Select
Increase
Access
Setup
Display
1
Stick Check Display
When stick check is On, a stick
check routine is performed at the
end of each weld. When Off, no
stick check is done.
Flow
Monitor
> Stick
Ramps
Stick
Check
> On
Stick
Check
> Off
1
14-20. Stick Check Selection
Press Mode
Select
Increase
Access
Setup
Display