Motorola SYMBOL MINISCAN MSXX04 User Manual
Page 91
Symbol MS3204 Specifications
7 - 9
Table 7-3
Symbol MS3204 Omnidirectional Decode Distances
Symbol Density/
p/n / Bar Code Type
Bar Code Content/
Contrast
1
Typical Working Ranges
3
Guaranteed Working
Ranges
3
Near
Far
Near
Far
6.0 mil
60-01755-01
Code 39
123
80% MRD
0.25 in.
0.64 cm
3.25 in.
8.3 cm
0.75 in.
1.9 cm
2.25 in.
5.7 cm
64-06629-01
80% UPC
0080015
80% MRD
1.0 in.
2.5 cm
6.5 in.
16.5 cm
1.5 in.
3.8 cm
4.5 in.
11.4 cm
13 mil
64-05303-01
100% UPC
012345678905
80% MRD
1.5 in.
3.8 cm
12.5 in.
31.2 cm
Note 2
9.5 in.
24.1 cm
20 mil 1D
60-02710-03
LC 35%
123
80% MRD
1.75 in.
4.4 cm
12.5 in.
31.8 cm
Note 2
10.0 in.
25.4 cm
Notes:
1. Contrast measured as Mean Reflective Difference (MRD) at 650 nm.
2. Near ranges on largely depend on the width of the bar code and the scan angle.
3. Working range specifications: Photographic quality symbols, pitch = 15°, skew = 0°, roll = 0°,
ambient light < 150 ft. candles, and temperature = 23 °C, Vcc = 5V.
4. Measured from the front of the scanner.