Parameter Menus 10 - 17
Programmable Raster Height And Raster Expansion Speed
Parameter # E4h, E5h
This parameter selects the laser pattern’s height and rate of expansion, and is only used when Programmable
Raster or Always Raster is enabled. This parameter is intended for very specific applications, and is usually not
necessary.
Select the laser pattern’s height and/or rate of expansion.
1.
Scan the bar code for either Raster Height or Raster Expansion Speed below.
2.
Scan two numeric bar codes beginning on
that represent a two-digit value. Valid values are
between 01 and 15.
To change the selection or to cancel an incorrect entry, scan
NOTE
This option is supported by the Symbol MS2204, MS2204VHD and MS3204-I000 only.
Raster Height (Default 15)