Delete character set ecis, Delete character set ecis -104, Delete character set ecis parameter # e6h – Motorola SYMBOL MINISCAN MSXX04 User Manual
Page 210
10 - 104Symbol MiniScan MSXX04 Series Integration Guide
Delete Character Set ECIs
Parameter # E6h
Select Delete Character Set ECIs to delete any escape sequences representing Character Set ECIs (also known
as GLIs) from its buffer before transmission. In many receiving systems, Character Set ECIs can be removed
without affecting the way data is displayed or processed.
Select Transmit Character Set ECIs to transmit data from PDF417 and MicroPDF417 bar codes containing
Character Set ECIs, even when the ECI Protocol is disabled.
Scan a bar code to delete or transmit character set ECIs.
Delete Character Set ECIs
(01h)
*Transmit Character Set ECIs
(00h)
NOTE
This option is supported by the MS2204, MS2204VHD and MS3204 only.