beautypg.com

Symbol ms3204 technical specifications, Symbol ms3204 technical specifications -5 – Motorola SYMBOL MINISCAN MSXX04 User Manual

Page 87

background image

Symbol MS3204 Specifications

7 - 5

Symbol MS3204 Technical Specifications

Table 7-2

Symbol MS3204 Technical Specifications @ 23°C

Item

Description

Power Requirements

Input Voltage

Scanning Current

Standby Current

V

cc

Noise Level

+5.0 VDC ± 10%

250 ± 30 mA typical

21 ± 5 mA typical

200 mV peak-to-peak max.

Laser Power

0.7 mW typical, 0.8 mW maximum,

λ = 650 nm

Scan Rate

640 scans/second

Scan Frequency: Horizontal

320 Hz ± 5 Hz

Scan Frequency: Vertical

282 Hz ± 5 Hz

Frame Rate

24 frames/sec. 12 Hz ±1 Hz (vertical)

Print Contrast

Minimum 35% absolute dark/light reflectance differential (PDF);
35% absolute dark/light reflectance differential (1D)

Scan Angle

Horizontal: 34

o

±1.5

o

Vertical: 12.5

o

±1.5

o

Scan Pattern

MS3204-I000: Omnidirectional, semi-omnidirectional, smart raster,
high density single scan line

MS3204-E000: Omnidirectional only

Start Time

0.065 sec. to 75% of steady state horizontal amplitude

Skew Tolerance

± 15

o

from normal (see

Figure 7-4 on page 7-7

)

Pitch Angle

± 30

o

from normal (see

Figure 7-4 on page 7-7

)

Roll

± 4

o

from vertical (see

Figure 7-4 on page 7-7

)

(For scanning benchmark label, assuming 3:1 codeword aspect ratio).
Note that this is dependent on the decoder.

Decode Depth of Field

See

Figure 7-5 on page 7-8

and

Figure 7-6 on page 7-10

Beam Deviation
(offset from the nominal)

Horizontal: ±3.0

o

Vertical: ±3.0

o

Horizontal tilt: ± 2

o

Additional Post Shock Beam
Deviation (2000G Shock)

Horizontal: ±3.0

o

max

Vertical: ±6.0

o

max