beautypg.com

Inspection/setup – Multiquip MQ POWER WHISPERWATT SERIES 60HZ GENERATOR (STD.) (KOMATSU SAA6D170E-3 DIESEL ENGINE) DCA800SSK2 User Manual

Page 30

background image

PAGE 30 — DCA800SSK2 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #0 (09/03/09)

INSPECTION/SETUP

Refueling Procedure:

Level Tanks

1.

— Make sure fuel cells are level with the

ground. Failure to do so will cause fuel to spill from the
tank before reaching full capacity (Figure 28).

Only Fill on Level Ground

Figure 28.

WARNING

Diesel fuel and its vapors are dangerous
to your health and the surrounding
environment. Avoid skin contact and/or
inhaling fumes.

CAUTION

ALWAYS place trailer on fi rm level ground before
refueling to prevent spilling and maximize the amount
of fuel that can be pumped into the tank.

NOTICE

ONLY use #2 diesel fuel when refueling.

Open cabinet doors on the “right side” of the generator

2.

(from generator control panel position). Remove fuel
cap and fi ll tank (Figure 29).

Fueling the Generator

Figure 29.

NEVER overfi ll fuel tank

3.

— It is important to read the

fuel gauge when fi lling trailer fuel tank. DO NOT wait
for fuel to rise in fi ller neck (Figure 30).

Full Fuel Tank

Figure 30.

Fuel Expansion

Figure 31.

CAUTION

DO NOT OVERFILL fuel system. Leave room for fuel
expansion. Fuel expands when heated (Figure 31).

This manual is related to the following products: