Initial set up/information> (continued) – MITSUBISHI ELECTRIC DX-NT400E User Manual
Page 54
54
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
■
INFORMATION/SERVICE
This menu is used to check the log list or list of power
failures, etc., and to initialize the menus.
At the bottom of the screen, the following information
appears.
• The accumulated operation time since the beginning of
usage (“ELAPSED TIME”)
• The HDD setting of MIRRORING, PARTITION, or
NORMAL mode (“HDD SETTING” and “PARTITION SIZE”)
>>HDD INFORMATION
WARNING LOG LIST
RESET TO FACTORY SETTINGS
MAIN HDD DATA CLEAR
SUB HDD DATA CLEAR
ELAPSED TIME: 6H
HDD SETTING PARTITION
PARTITION SIZE 10
%
“SUB HDD DATA CLEAR” and “PARTITION
SIZE” appear when “HDD SETTING” in
♦
HDD INFORMATION
This menu is used to check the recorded range of the HDD.
A: HDD(120GB)
B: HDD(120GB)
MAIN START 02-02-2003 00:00:00
END 04-04-2003 00:00:00
SUB START 02-02-2003 00:00:00
END 04-04-2003 00:00:00
Recording start and end times of “SUB” HDD
appear when “HDD SETTING” in
screen is set to “PARTITION.”
1. (To check the recorded range of the HDD • • • )
Press the SET UP button
}
}
UP/INFORMATION> } Select “HDD INFORMATION” in the 2. Press the CLEAR button or the SET UP button. ♦ WARNING LOG LIST This menu is used to check the number, date, time, and The failures displayed in the WARNING LOG LIST: ( “P-LOSS”: Power failure. “SYS RST”: Reset button is pressed and the unit is “ALM OFF”: ALARM INTERRUPT button is pressed “ALM ON”: Alarm interrupt is cancelled manually by 1. Press the SET UP button } } UP/INFORMATION> } Select “WARNING LOG LIST” in the • The button : Selection moves to the next number. • JOG button : Selection moves to the previous number. • JOG button : Displays the page with date prior to the date of the currently opened page. • JOG button : Displays the page with date newer than the When a failure occurs while the LIST> screen is displayed, exit the screen and display 2. Press the CLEAR button or the SET UP button. ♦ RESET TO FACTORY SETTINGS This menu is used to initialize menu screen settings. >>EXECUTE ENTER:EXECUTE,CLEAR:CANCEL 1. Press the SET UP button } } UP/INFORMATION> } Select “RESET TO FACTORY SETTINGS” in the • The 2. Press the ENTER button. • The menu screen settings are initialized. 3. Press the CLEAR button or the SET UP button. The setting of present time, password, and timer program are not reset. When you execute RESET TO FACTORY SETTINGS with the setting of IP ADDRESS, SUB NET
setting and determine such setting.
type of failures.
NO DATE TIME WARNING
>>0003 04-03-03 15:03:27 P-LOSS
0002 26-02-03 09:56:43 ALM ON
0001 02-02-03 10:00:00 ALM OFF
see page 81).
reset.
and the unit is put on interruption.
pressing ALARM INTERRUPT button. Alarm
interrupt is cancelled automatically after 5 minutes
from the start of interruption.
• The WARNING LOG LIST displays up to 1000 items. When
the number of items exceeds this limit, the latest 1000 items
are displayed.
• JOG
date of the currently opened page.
the screen again. A new item will be added to the list.
the ENTER button.
• When cancelling the intialization of the menu screen
settings, press the CLEAR button.
MASK, GATEWAY, SERVICE PORT SETTING in
OWN in
changed, the power turns off and the unit boots-up.