INFORMATION/SERVICE

This menu is used to check the log list or list of power
failures, etc., and to initialize the menus.

At the bottom of the screen, the following information
appears.
• The accumulated operation time since the beginning of
usage (“ELAPSED TIME”)
• The HDD setting of MIRRORING, PARTITION, or
NORMAL mode (“HDD SETTING” and “PARTITION SIZE”)


>>HDD INFORMATION
WARNING LOG LIST
RESET TO FACTORY SETTINGS
MAIN HDD DATA CLEAR
SUB HDD DATA CLEAR

ELAPSED TIME: 6H
HDD SETTING PARTITION
PARTITION SIZE 10

%

“SUB HDD DATA CLEAR” and “PARTITION

SIZE” appear when “HDD SETTING” in ZATION> screen is set to “PARTITION.”

HDD INFORMATION

This menu is used to check the recorded range of the HDD.



A: HDD(120GB)
B: HDD(120GB)

MAIN START 02-02-2003 00:00:00
END 04-04-2003 00:00:00
SUB START 02-02-2003 00:00:00
END 04-04-2003 00:00:00

Recording start and end times of “SUB” HDD

appear when “HDD SETTING” in
screen is set to “PARTITION.”

1. (To check the recorded range of the HDD • • • )
Press the SET UP button

}

}

UP/INFORMATION>

}

Select “HDD INFORMATION” in the

screen. Display the desired
setting and determine such setting.

2. Press the CLEAR button or the SET UP button.

WARNING LOG LIST

This menu is used to check the number, date, time, and
type of failures.


NO DATE TIME WARNING
>>0003 04-03-03 15:03:27 P-LOSS
0002 26-02-03 09:56:43 ALM ON
0001 02-02-03 10:00:00 ALM OFF

The failures displayed in the WARNING LOG LIST: (
see page 81).

“P-LOSS”: Power failure.

“SYS RST”: Reset button is pressed and the unit is
reset.

“ALM OFF”: ALARM INTERRUPT button is pressed
and the unit is put on interruption.

“ALM ON”: Alarm interrupt is cancelled manually by
pressing ALARM INTERRUPT button. Alarm
interrupt is cancelled automatically after 5 minutes
from the start of interruption.

1. Press the SET UP button

}

}

UP/INFORMATION>

}

Select “WARNING LOG LIST” in the

screen. Press the ENTER button.

• The screen appears.
• The WARNING LOG LIST displays up to 1000 items. When
the number of items exceeds this limit, the latest 1000 items
are displayed.
• JOG

button : Selection moves to the next number.

• JOG

button : Selection moves to the previous number.

• JOG

button : Displays the page with date prior to the

date of the currently opened page.

• JOG button : Displays the page with date newer than the
date of the currently opened page.

When a failure occurs while the

LIST> screen is displayed, exit the screen and display
the screen again. A new item will be added to the list.

2. Press the CLEAR button or the SET UP button.

RESET TO FACTORY SETTINGS

This menu is used to initialize menu screen settings.

>>EXECUTE

ENTER:EXECUTE,CLEAR:CANCEL

1. Press the SET UP button

}

}

UP/INFORMATION>

}

Select “RESET TO FACTORY

SETTINGS” in the screen. Press
the ENTER button.

• The screen appears.
• When cancelling the intialization of the menu screen
settings, press the CLEAR button.

2. Press the ENTER button.

• The menu screen settings are initialized.

3. Press the CLEAR button or the SET UP button.

The setting of present time, password, and timer

program are not reset.

When you execute RESET TO FACTORY

SETTINGS with the setting of IP ADDRESS, SUB NET
MASK, GATEWAY, SERVICE PORT SETTING in
screen or IP ADDRESS, TARGET,
OWN in screen
changed, the power turns off and the unit boots-up.