HOLIDAY SETTING
This menu is used to set holidays throughout the year.
--
/-- --/-- --/-- --/--
--/-- --/-- --/-- --/--
--/-- --/-- --/-- --/--
--/-- --/-- --/-- --/--
--/-- --/-- --/-- --/--
DAY/MONTH
1. Press the SET UP button
}
}
Select
“HOLIDAY SETTING” in the
screen and determine desired holidays.
2. Press the CLEAR button or the SET UP button.
When setting a holiday in “HOLIDAY SETTING”
and select “HOL” in the day of the week settings, the
program selected with “HOL” is given priority over
the other programs.
■
Recording mode settings A to D for normal
recording and alarm recording
The recording camera, recording intervals, and recording
picture quality for normal recording/alarm recording can be
set to 4 patterns of recording mode, A to D (
see pages
25 and 26 for “Setting the recording interval and recording
picture quality for normal recording,” pages 41 to 43 for
“Recording mode settings for normal recording and alarm
recording”).
1. Press the SET UP button
}
}
Select “REC
MODE A” in the
then press the ENTER button.
• The
>>ALARM SETTING
RECORD SETTING
2. Press the JOG , buttons to select either “ALARM
SETTING” or “RECORD SETTING” and determine such
setting.
•
see page 41 for “ALARM SETTING,” page 42 for
“RECORD SETTING,” page 43 for “PRE ALARM REC.”
When you set “SHORT,” “MEDIUM,” or “LONG”
in the PRE ALARM REC, normal recording cannot
be performed. Set the PRE ALARM REC to “OFF”
to perform normal recording or alarm recording.
When you set “A-PPS” in the SETTING> screen to “- - - - - -” for all the cameras, 3. To continue with REC MODE B to REC MODE D, repeat The storage area in MAIN HDD set in “PARTI- TION” is displayed with the percentage (%) and the see page 70). ■ ALARM REC DURATION The recording time period for alarm recording can be set see page 43). ♦ Overlapped timer program settings When the programmed period of timer program settings Example 1 • Program 1 is set for 14:00 to 17:00 with the PPS of 5P. Under this condition, the unit will give priority to Program 2 for 14:00 15:00 16:00 17:00 14:00 15:00 16:00 17:00 Example 1) In Program 1, recording is set for PPS 1P In Program 2, recording is set for PPS Actual recorded contents 5P 5P Program 2 5P 1P Program 1 Program 1 Example 2 • Program 1 is set for 14:00 to 17:00 with the PPS of 5P. Again, the unit will give priority to Program 2 for the duration 14:00 15:00 16:00 17:00 14:00 15:00 16:00 17:00 5P 5P NO RECORDING! Example 2) SKIP In Program 2, the SKIP setting is 5P Actual recorded contents Program 2 Program 1 Program 1 In Program 1, recording is set for PPS
pre-alarm recording is not performed even if PRE
ALARM REC is set to “SHORT,” “MEDIUM,” or
“LONG.” In this case, normal recording is performed
at the interval which is set in “PPS.”
steps 1 and 2.
recordable time of that storage area is displayed in
(for ALARM REC DURATION,
are overlapped, the unit gives priority to the higher-
numbered program.
• Program 2 is set for 15:00 to 16:00 with the PPS of 1P.
the duration of the overlapping period, from 15:00 to 16:00.
The unit will operate as shown in the chart below.
to 5P, from 14:00 to 17:00.
to 1P, from 15:00 to 16:00.
• Program 2 is set for 15:00 to 16:00 with the SKIP setting.
of the overlapping period. As shown in the illustration below,
the unit will activate the Skip setting from 15:00 to 16:00.
entered for 15:00 to 16:00.
to 5P, from 14:00 to 17:00.