beautypg.com

Motorola LS3478 User Manual

Page 40

background image

3 - 4

Symbol LS3478 Product Reference Guide

Scanner emits short low-short
high- short low-short high beep
sequence while it is being
programmed.

Out of ADF parameter
storage space.

Erase all rules and re-program with shorter rules.

Out of Synapse parameter
storage space.

Scan ’Set Synapse Defaults’ bar code, from the
appropriate Synapse Interface Guide, for cables
no longer in use and re-program the scanner for
the current host interface.

Scanner emits one short high
beep when it is not in use.

In RS-232 mode, a
character is received and
Beep on option is
enabled.

Normal when Beep on is enabled and the
scanner is in RS-232 mode.

Scanner emits short low-short
medium-short high beep
sequence.

Scanner is powering up.

Normal when scanner battery is inserted.

Battery does not charge.

Cradle is outside the
charging temperature range.

Charge within the recommended temperature of
32° to 104° F
(0° to 40° C) nominal, 41° to 95° F (5° to 35° C)
ideal.

Table 3-1

Troubleshooting (Continued)

Problem

Possible Causes

Possible Solutions

NOTE

If problems still occur, contact the distributor or contact Motorola Enterprise Mobility Support. See

page xv