beautypg.com

Table b-3 – Motorola LS3478 User Manual

Page 309

background image

Programming Reference

B - 3

The modifier character is the sum of the applicable option values based on

Table B-3

.

Table B-3

Modifier Characters

Code Type

Option Value

Option

Code 39

0

No check character or Full ASCII processing.

1

Reader has checked one check character.

3

Reader has checked and stripped check character.

4

Reader has performed Full ASCII character conversion.

5

Reader has performed Full ASCII character conversion and checked
one check character.

7

Reader has performed Full ASCII character conversion and checked
and stripped check character.

Example: A Full ASCII bar code with check character W, A+I+MI+DW, is transmitted as
]A7AIMID where 7 = (3+4).

Trioptic Code 39

0

No option specified at this time. Always transmit 0.

Example: A Trioptic bar code 412356 is transmitted as ]X0412356

Code 128

0

Standard data packet, no Function code 1 in first symbol position.

1

Function code 1 in first symbol character position.

2

Function code 1 in second symbol character position.

Example: ACode (EAN) 128 bar code with Function 1 character

FNC1

in the first position,

AIMID is transmitted as ]C1AIMID

I 2 of 5

0

No check digit processing.

1

Reader has validated check digit.

3

Reader has validated and stripped check digit.

Example: An I 2 of 5 bar code without check digit, 4123, is transmitted as ]I04123

Codabar

0

Standard Codabar.

1

ABC Codabar.

3

Reader has stripped check digit before transmission.

Example: A Codabar bar code without check digit, 4123, is transmitted as ]F04123

Code 93

0

No options specified at this time. Always transmit 0.

Example: A Code 93 bar code 012345678905 is transmitted as ]G0012345678905