beautypg.com

8 emc filter, Options and auxiliary equipment, 2) connection example – MITSUBISHI ELECTRIC MR-J2S- CL User Manual

Page 294: 3) outline drawing

background image

14 - 41

14. OPTIONS AND AUXILIARY EQUIPMENT

14.2.8 EMC filter

For compliance with the EMC Directive of the EN Standard, it is recommended to use the following filter:
Some EMC filters are large in leakage current.

(1) Combination with the servo amplifier

Recommended filter

Servo amplifier

Model

Leakage current [mA]

Weight [kg]([lb])

MR-J2S-10CL to MR-J2S-100CL
MR-J2S-10CL1 to MR-J2S-40CL1

SF1252

38

0.75 (1.65)

MR-J2S-200CL MR-J2S-350CL

SF1253

57

1.37 (1.65)

MR-J2S-500CL

(Note)

HF-3040A-TM

1.5

5.5 (12.13)

MR-J2S-700CL

(Note)

HF-3050A-TM

1.5

6.7 (14.77)

Note : Soshin Electric. A surge protector is separately required to use any of these EMC filters. (Refer to the EMC Installation

Guidelines.)

(2) Connection example

NFB

L

1

L

2

L

3

L

11

L

21

L

1

L

2

L

3

LINE

LOAD

3-phase

200 to 230V AC,

1-phase

230VAC or

1-phase

100 to120VAC

EMC filter

Servo amplifier

(Note 1) Power supply

(Note 2)

Note: 1. For 1-phase 230VAC power supply, connect the power supply to L

1

,L

2

and leave L

3

open.

There is no L

3

for 1-phase 100 to 120VAC power supply.

2. Connect when the power supply has earth.

L

1

L

2

L

3

(3) Outline drawing

23.0(0.906)

LAB

E

L

LI

N

E

LOA

D

16

8.0(

6

.6

1

4

)

L1'
L2'
L3'

L1
L2
L3

149.5(5.886)

LINE
(input side)

LOAD
(output side)

14

0.0(

5

.5

1

2

)

15

6.0(

6

.1

4

2

)

16.0(0.63)

42.0

8.5

SF1252

LAB

E

L

LI

N

E

LOA

D

16

8.0(

6

.6

1

4

)

L1'
L2'
L3'

L1
L2
L3

209.5(8.248)

LINE
(input side)

LOAD
(output side)

14

0.0(

5

.5

1

2

)

15

6.0(

6

.1

4

2

)

49.0

8.5

SF1253

[Unit: mm(in)]

(0.335)

(1.654)

(0.335)

(1.929)

6.0(0.236)

6.0(0.236)