4 - 18
4. OPERATION
5) Program example 5
Program
Description
SPN (1000)
STC (20)
MOVI (1000)
TIM (20)
SYNC (1)
MOVI (500)
STOP
Speed (Motor speed)
1000 [r/min]
Acceleration/deceleration time constant
20 [ms]
Incremental move command
1000 [ 10
STM
m]
Dwell command time
200 [ms]
a)
Step is suspended until Program input (PI1) turns ON.
Incremental move command
500 [ 10
STM
m]
Program end
0r/min
ON
OFF
Forward
rotation
Servo motor
speed
Program input1
(PI1)
a) PI1 is accepted in 200ms or later.
6) Program example 6
Program
Description
SPN (1000)
STC (20)
MOVI (1000)
SYNC (1)
TIM (20)
MOVI (500)
STOP
Speed (Motor speed)
1000 [r/min]
Acceleration/deceleration time constant
20 [ms]
Incremental move command
1000 [ 10
STM
m]
Step is suspended until Program input (PI1) turns ON.
Dwell command time
200 [ms]
a)
Incremental move command
500 [ 10
STM
m]
Program end
0r/min
ON
OFF
Forward
rotation
Servo motor
speed
Program input1
(PI1)
a) 200ms