Rs-232 / telnet / udp commands – Gefen DVI MATRIX EXT-DVI-16416 User Manual

Page 23

background image

19

RS-232 / TELNET / UDP COMMANDS

#ediddstoba Command
The #ededdstoba command reads the downstream EDID and stores it to a

specified EDID bank.

Syntax:
#ediddstoba param1 param2

Parameters:
param1

A downstream monitor

[1 ... 16]

param2

EDID bank offset

[1 ... 3]

#ediddstolo Command

The #ediddstolo

command reads the downstream EDID and stores it to a Local EDID input.

Syntax:
#ediddstolo param1 param2 [param3...param9]

Parameters:
param1

A downstream monitor

[1 ... 16]

param2

Input list

[1 ... 16]

Notes:
If param2 = 0, then the downstream EDID is stored to all 16 DVI inputs. If more than eight

inputs need to be specified in order to receive the downstream EDID,

the #ediddstolo command must be executed twice.

Example:

#ediddstolo 2 1 2 3 4 5 6 7 8 9 10 11 (not permitted!)

Instead, run the function twice:

#ediddstolo 2 1 2 3 4 5 6 7 8 9

#ediddstolo 2 10 11